A03S Access Control Admin Guide
AKUVOX SMART INTERCOM
www.akuvox.com
18
Parameter Set-up:
Enable:
enable the HTTP command unlock function by clicking on
Enable
field.
User Name:
enter the user name of the device web interface, for example:
“
Admin
”.
Password
: enter the password for the HTTP command. For example:
“
12345
”.
Please refer to the following example:
http://192.168.35.127/fcgi/do?action=OpenDoor&UserName=admin&Passw
ord=12345&DoorNum=1
Note:
DoorNum
in the HTTP command above refers to the relay number #1
to be triggered for the door access.
12.1.4. Unlock by Exit Button
When you need to open the door from inside using the exit button installed by
the door, you can configure the access control terminal Input to trigger the
relay for the door access. To configure the configuration on web
Hardware >
Input
interface.