Akuvox A03S Manual Download Page 1

About This Manual

Thank you for choosing Akuvox A03S access control terminal. This manual is

intended for the administrators who need to properly configure the access

control terminal. This manual applies to 103.30.2.23 version, and it provides

all the configurations for the functions and features of A03S access control

terminals. Please visit Akuvox forum or consult technical support for any

new information or the latest firmware.

Summary of Contents for A03S

Page 1: ...istrators who need to properly configure the access control terminal This manual applies to 103 30 2 23 version and it provides all the configurations for the functions and features of A03S access control terminals Please visit Akuvox forum or consult technical support for any new information or the latest firmware ...

Page 2: ...in order to prevent the persons from injury Caution Always abide by this information in order to prevent the damages to the device Note Informative information and advice from the efficient use of the device Tip Useful information for the quick and efficient use of the device ...

Page 3: ...Related Documentation You are advised to refer to the related documents for more technical information via the link below https knowledge akuvox com ...

Page 4: ... may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient o...

Page 5: ... 1 Configure Door Access Schedule 13 11 1 1 Create Door Access Schedule 13 11 1 2 Import and Export Door Access Schedule 14 12 Door Unlock Configuration 16 12 1 Configure RF Card for Door Unlock 16 12 1 1 Configure RF Card on the Web Interface 16 12 1 1 1 Configure RF Card Code Format 16 12 1 2 Unlock by NFC 17 12 1 3 Unlock by HTTP Command on Web Browser 17 12 1 4 Unlock by Exit Button 18 12 1 5 ...

Page 6: ...ration 31 18 5 Static Provisioning Configuration 33 19 Integration with Third Party Device 36 19 1 Integration via Wiegand 36 19 2 Integration via HTTP API 37 20 Password Modification 38 20 1 Modify the Password 38 20 2 Web Interface Automatic Log out 38 21 System Reboot and Reset 39 21 1 Reboot 39 21 2 Reset 39 22 Abbreviations 40 23 FAQ 42 24 Contact Us 43 ...

Page 7: ...standalone device thus saving your solution costs Equipped with a card reader 125kHz and 13 56MHz which is capable of handling a majority of cards in wide use currently A03S is designed to provide you with greater flexibility and security than those traditional access control systems A03S access control terminal applies to residential buildings office buildings and their complex ...

Page 8: ...A03S Access Control Admin Guide AKUVOX SMART INTERCOM www akuvox com 2 2 Change Log The change log will be updated here along with the changes in new software version ...

Page 9: ...ecification Model Feature A03S Housing Material Front panel Toughened Glass Frame Aluminum Alloy Relay Out 1 Input 2 Wiegand PoE RAM 128M ROM 128M Card Reader 13 56MHz 125KHz Wi Fi X Bluetooth IP Rating IP65 LTE X USB X External SD Card X Wall Mounting Flush Mounting Desk Mounting X ...

Page 10: ...stem this section covers network and time setting firmware upgrade device reset reboot configuration file auto provisioning system log and PCAP password modification as well as device backup Tool selection Akuvox has many configuration tools for you to set up devices more conveniently Here we list some common tools please contact your administrator to get the tool if you need them 1 ACMS ACMS Acce...

Page 11: ...er tool to search the device IP address in the same LAN Then use the IP address to login in the web browser by user name and password admin and admin Tip Please refer to the URL below for the IP scanner application instructions https knowledge akuvox com v1 en Note Google Chrome browser is strongly recommended The Initial user name and password are admin and please be case sensitive to the user na...

Page 12: ...me zone setting in your device To configure the configuration on the device web System Time interface Parameter Set up Time Zone select the specific time zone depending on where the device is used and then press Confirm tab for the confirmation The default time zone is GMT 0 00 Primary Server enter the primary NTP server you obtained in the NTP Server field Alternate Server enter the secondary NTP...

Page 13: ...he related parameters in web Hardware LED interface Parameter Set up Backlight Intensity adjust the backlight intensity the bigger value the brighter backlight Backlight Enabled tick the check box if want to enable the card reader LED lighting and vice versa Start Time End Time H enter the time span for the LED lighting to be valid e g if the time span is from 18 22 it means LED light will stay on...

Page 14: ...or open door notification Moreover you can also set up the tamper alarm volume when unwanted removal of the access control terminal occurs To configure the configuration on web Hardware Audio Volume Control interface Parameter Set up Tamper Alarm Volume set the tamper alarm volume from 0 15 according to your need The default volume is 8 Voice Prompt Volume set the voice prompt volume from 0 15 acc...

Page 15: ...dress automatically Static IP select the static IP mode by checking off the Static IP check box When static IP mode is selected then the IP address subnet mask default gateway and DNS servers address must be manually configured according to your actual network environment IP Address set up the IP Address if the static IP mode is selected Subnet Mask set up the subnet mask according to your actual ...

Page 16: ...s after you press unlock tab Hold Delay Sec set the relay hold delay timing Ranging from 1 10 Sec For example if you set the hold delay time as 5 Sec then the relay will be delayed for 5 after the door is unlocked Relay Status relay status is low by default which means normally closed NC If the relay status is high then it is in Normally Open status NO Relay Name name the relay switch according to...

Page 17: ...needs to set up on the web interface where you are required to fill in such information as relay IP address password web relay action etc Before you can achieve the door access via web relay To configure the configuration on web Services Web Relay interface Parameter Set up Type select among three options Disabled WebRelay and Both Select WebRelay to enable the web relay Select Disable to disable ...

Page 18: ...sing http get in Action Web Relay Action enter the specific web relay action command provided by the web manufacturer for different actions by the web relay http admin admin 192 168 1 2 state xml relayState 2 After the web relay is set up you can configure the specific web relay to be triggered based on the relay location for the door access To configure the configuration on web Directory User Acc...

Page 19: ... access control intended for individual user or a group of users created Moreover you can edit your door access schedule if needed 11 1 1 Create Door Access Schedule You can create the door access schedule on the daily or weekly basis and you can also create schedule that allows you to plan for a longer period of time in addition to running the door access schedule on the daily or monthly basis To...

Page 20: ...reate a longer period schedule select Schedule Mode as Normal 11 1 2 Import and Export Door Access Schedule In addition to creating door access schedule separately you can also conveniently import or export the schedules in order to maximize your door access schedule management efficiency To configure the configuration on web Directory Schedule interface ...

Page 21: ...A03S Access Control Admin Guide AKUVOX SMART INTERCOM www akuvox com 15 Note It only supports xml format file for importing and exporting the schedule ...

Page 22: ...igure RF Card on the Web Interface To configure the configuration on web Directory User RF Card interface You need to click Add tab to turn to RF Card interface Note RF card with 13 56 MHz and 125 KHz can be applicable to the access control terminal for the door access 12 1 1 1 Configure RF Card Code Format If you want to integrate with the third party intercom system in terms of RF card door acce...

Page 23: ...n interaction A0X supports to be unlocked by NFC You can keep the mobile phone closer to the door phone for the door access To configure the configuration on web Hardware Card Reader NFC interface Note NFC feature is only supported by Android telephone 12 1 3 Unlock by HTTP Command on Web Browser You can unlock the door remotely without approaching the device physically for the door access by typi...

Page 24: ...2345 Please refer to the following example http 192 168 35 127 fcgi do action OpenDoor UserName admin Passw ord 12345 DoorNum 1 Note DoorNum in the HTTP command above refers to the relay number 1 to be triggered for the door access 12 1 4 Unlock by Exit Button When you need to open the door from inside using the exit button installed by the door you can configure the access control terminal Input ...

Page 25: ...ample if you set the delay time as 5 then the action will not be triggered until 5 seconds after input status changed Execute Relay set up relays to be triggered by the input Door Status display the status of input signal 12 1 5 Unlock by Bluetooth You can also gain door access by mobile phone with Bluetooth which is used together with Akuvox MobileKey App now You can use the mobile phone closer t...

Page 26: ...Valid Time for the security you can setup the authentication code valid time to avoid codes being paired indefinitely The time can be set up from 1h to 24h You can set up on Directory User click Add to enter BLE Setting interface Parameter Set up Authentication Code click Generate to create a paring code for the App The app will using this code to match with A03S Status Shows whether the current a...

Page 27: ...m Security Tamper Alarm interface Parameter Set up Enable tick the check box to enable the tamper alarm function When the tamper alarm goes off you can press the Disarm tab beside the check box to clear the alarm Key Status temper alarm will not be triggered unless the key status is shifted from Low to High status Note Disarm tab will turn gray when the temper alarm is cleared The round rubber but...

Page 28: ...ification interface Parameter Set up Sender s Email Name enter the name of the email sender Sender s email address enter the sender s email address from which the email notification will be sent out Receiver s email address enter the receiver s email address Receiver s Email Name enter the name of the email receiver SMTP server address enter the SMTP server address of the sender Port enter the por...

Page 29: ...X SMART INTERCOM www akuvox com 23 SMTP password configure the password of SMTP service which is same with sender s email address Email subject enter the subject of the email Email content compile the emails contents according to your need ...

Page 30: ...rameter Set up Save Door Log Enabled Tick the check box to turn on or turn off the door log function Status select between Success and Failed options to search for successful door accesses or Failed door accesses Time select the specific time span of the door logs you want to search check or export Name Code select the Name and Code options to search door log by the name or by the PIN code Type di...

Page 31: ...el select log levels from 1 to 7 levels You will be instructed by Akuvox technical staff about the specific log level to be entered for debugging purpose The default log level is 3 the higher the level is 5 the more complete the log is 7 Export Log click the Export tab to export temporary debug log file to a local PC Remote System Log Enabled select Enable or Disable if you want to enable or disab...

Page 32: ... the data packet from the specific port can be captured You can leave the field blank by default PCAP click Start tab and Stop tab to capture a certain range of data packets before clicking Export tab to export the data packets to your Local PC PCAP Auto Refresh Enabled select Enable or Disable to turn on or turn off the PCAP auto fresh function If you set it as Enable then the PCAP will continue ...

Page 33: ...KUVOX SMART INTERCOM www akuvox com 27 16 Firmware Upgrade Firmware of different versions for A03S access control terminal can be upgraded on the device web System Upgrade interface Note Firmware files should be rom format for upgrade ...

Page 34: ...trol Admin Guide AKUVOX SMART INTERCOM www akuvox com 28 17 Backup Configuration files can be imported to or exported out of the device to your local PC on the device web System Maintenance Others interface if needed ...

Page 35: ...g up configuration needed one by one manually on the access control terminal 18 1 Provisioning Principle Auto provisioning is a feature used to configure or upgrade the devices in batch via third party servers DHCP PNP TFTP FTP HTTPS are the protocols used by the Akuvox intercom devices to access the URL of the address of the third party server which stores configuration files and firmware which w...

Page 36: ...0083 cfg MAC based configuration provisioning MAC based configuration files is used for the auto provisioning on a specific device as distinguished by its unique MAC number And the configuration files named with device MAC number will be matched automatically with the device MAC number before being downloaded for the provisioning on the specific device Note If a server has these two types of confi...

Page 37: ...p or according to the schedule you set up Hourly Repeat select Hourly Repeat if you want the device to perform Autop every hour 18 4 DHCP Provisioning Configuration Auto provisioning URL can also be obtained using DHCP option which allows device to send a request to a DHCP server for a specific DHCP option code If you want to use Custom Option as defined by users with option code range from 128 25...

Page 38: ... com 32 Note The custom Option type must be a string The value is the URL of TFTP server Parameter Set up Custom Option enter the DHCP code that matched with corresponding URL so that device will find the configuration file server for the configuration or upgrading ...

Page 39: ...rver URL in it Note The general configuration file for the in batch provisioning is with the format r0000000000xx cfg taking A03S as an example r000000000101 cfg 10 zeros in total while the MAC based configuration file for the specific device provisioning is with the format MAC_Address of the device cfg for example 0C110504AE5B cfg 18 5 Static Provisioning Configuration You can manually set up a s...

Page 40: ...lank Password set up a password if the server needs a password to be accessed to otherwise leave it blank Common AES Key set up AES code for the intercom to decipher general Auto Provisioning configuration file AES Key MAC set up AES code for the intercom to decipher the MAC based auto provisioning configuration file Note AES is one type of encryption it should be configured only when the config f...

Page 41: ... allows anonymous login ftp username password 192 168 0 19 requires a user name and password HTTP http 192 168 0 19 use the default port 80 http 192 168 0 19 8080 use other ports such as 8080 HTTPS https 192 168 0 19 use the default port 443 Tip Akuvox do not provide user specified server Please prepare TFTP FTP HTTP HTTPS server by yourself ...

Page 42: ...ld be identical between the access control terminal and the device to be integrated Wiegand Transfer Mode set the transfer mode between Input or Output if the access control terminal is used as a receiver then set it as Input for the access control terminal and vice versa Wiegand Input Data Order set the Wiegand input data sequence between Normal and Reversed if you select Reversed then the input ...

Page 43: ... for the third party integration For example if the function is disabled any request to initiate the integration will be denied and be returned HTTP 403 forbidden status Auth Mode select among four options None WhiteList Basic Digest for authorization type which will be explained in detail in the following chart User Name enter the user name when Basic and Digest authorization mode is selected The...

Page 44: ...can also select the user role when setting passwords 20 2 Web Interface Automatic Log out You can set up the web interface automatic log out timing requiring re login by entering the user name and the passwords for the security purpose or for the convenience of operation To configure the configuration on web System Security Session Time Out interface Parameters Set up Session Time Out Value if the...

Page 45: ...ystem Upgrade Basic interface as well Moreover you can set up schedule for the device to be restarted To set up the device restart schedule on web System Auto Provisioning Reboot Schedule interface 21 2 Reset If you want to reset the device system to the factory setting you can it on the web System Upgrade interface You can also hold the reset button 12s on the back of A03S to reset ...

Page 46: ... COM Common CPE Customer Premise Equipment CWMP CPE WAN Management Protocol DTMF Dual Tone Multi Frequency DHCP Dynamic Host Configuration Protocol DNS Domain Name System DND Do Not Disturb DNS SRV Service record in the Domain Name System FTP File Transfer Protocol GND Ground HTTP Hypertext Transfer Protocol HTTPS Hypertext Transfer Protocol Secure Socket Layer IP Internet Protocol ID Identificati...

Page 47: ...ened NC Normal Connected NTP Network Time Protocol NAT Network Address Translation NVR Network Video Recorder ONVIF Open Network Video Interface Forum SIP Session Initiation Protocol SNMP Simple Network Management Protocol STUN Session Traversal Utilities for NAT SNMP Simple Mail Transfer Protocol SDMC SIP Devices Management Center TR069 Technical Report069 TCP Transmission Control Protocol TLS Tr...

Page 48: ...he same LAN network Q2 What is the supported temperature range for A03S A2 Working Temperature 20 C 55 C Storage Temperature 30 C 70 C Q3 Do Akuvox devices support Modbus protocol A3 No Q4 Do access control terminals support these card types Prox Legacy iClass iClassSE HID Mifare HID DESFire and HID SEOS A4 Sorry they are not supported They need to be implemented via hardware modifications ...

Page 49: ...ontact Us For more information about the product please visit us at www akuvox com or feel free to contact us by Sales email sales akuvox com Technical support email support akuvox com Telephone 86 592 2133061 ext 7694 8162 We highly appreciate your feedback about our products ...

Reviews: