3.  Timer operation 

 
This is the recommended operating mode. Use the stepless control dial to select an operating time between0 - 90 
minutes (see description of the control panel). 

 

The timer operation works on the basis of an "egg timer" and after the set operating time has elapsed, the ozone 
production switches off automatically. 

 

During ozone operation/production, the red signal light is on (see description of the control panel). 
 

4.  Continuous operation 

 
In this operating mode, the ozone production no longer switches off automatically and runs permanently. This 
operating mode is only recommended if you want an ozone treatment time of more than 90 minutes or if the user 
wants to monitor the operating room/object with ozone protective equipment (face mask). 

 

To switch on the ozone continuous operation, you must also switch the small round continuous operation switch to 
ON (see description of the control panel). 

 

During ozone operation/production, the red signal light is on (see description of the control panel). 
 
 

5.  Recommendations for the duration of treatment 

 
The treatment time depends on factors such as room temperature, room size, inventory type, object type, load 
intensity and air circulation. 

 

We recommend a room temperature between 20°C - 25°C and a humidity of less than 65 % relative humidity. If 
people or animals are present in the room shortly after the ozone treatment, the room temperature should be 
slightly lower after the treatment than during the treatment to ensure that ozone does not form again due to natural 
reactions. 

 

Except for large rooms, a desired high depth of effect and very aggressive odours (e.g. fire smell, butyric acid), a 
treatment time of maximum 6 hours should be sufficient. If the problem is not eliminated after this time, it is more 
advisable to repeat the treatment than to run the risk of too high ozone concentrations. 
 

Below are a few non-binding guideline values for the treatment duration at full ozone output level 
(5 g/h). Unless otherwise stated, these values apply to a room size of up to approx. 30 m² (75 m³): 

 
Category I odours 
(tobacco odours, animal odours, food odours, waste odours, etc.)  

 

Between 30 and 90 minutes 
 
Category II odours 
(Burning odours, musty odours, toilet odours, acid odours and chemical odours such as paints, varnishes, solvents, 
etc.). 

 

Between 90 and 800 minutes 
 
Mould remediation 

 

Between 90 and 800 minutes 
 
Disinfection: 

 

Between 30 and 80 minutes 

 

Automotive treatment: 

 

Between 30 and 80 minutes 
 
 

Summary of Contents for WDH-AP005

Page 1: ...ct To ensure that you get a lot of enjoyment from this product here are a few more tips In case of any problems We hope that the unit meets your expectations If despite the greatest possible care ther...

Page 2: ...harmful to health Precautions must be taken to prevent uncontrolled release of ozone The MAK value valid in Germany MAK Maximum Workplace Concentration is currently 0 1 ppm or 0 2 mg ozone m In addit...

Page 3: ...ds through chemical reactions All germs and bacteria as well as mould are also killed by ozone The shelf life of ozone depends among other things on the temperature and humidity Ozone starts to decomp...

Page 4: ...ere the ozone generator is to be used in order to be able to quickly interrupt the operation of the ozone generator at any time We therefore recommend that you connect the ozone generator to a power s...

Page 5: ...epends on factors such as room temperature room size inventory type object type load intensity and air circulation We recommend a room temperature between 20 C 25 C and a humidity of less than 65 rela...

Page 6: ...ide e g due to its construction and the ozone treatment phase lasted longer than 80 minutes we do not recommend that humans and animals stay in this room for approx 60 minutes In case of an ozone trea...

Page 7: ...observance of the assembly instructions Completely or partially dismantled units Conformity The ozone generator has been tested and itself and or parts thereof have been manufactured under the follow...

Reviews: