3.) The right location 
 

We recommend that you place the air purifier under the following aspects: 
 

  Central to achieving the highest possible effectiveness.  

  Near possible sources of dirt (workplaces). 

  With a clearance of 50 cm on all sides. 

  With a distance of approx. 100 cm to other electrical appliances and/or machines. 

 
Note: 

When large amounts of dust are generated, an air purifier alone may not be 

sufficient to ensure high air quality. If necessary, we recommend creating an additional 
air exchange by opening windows and doors ! 
Furthermore, you can connect up to four (4) WDH-AF500B industrial air cleaners to 
each other to increase the filter capacity (see picture on the right). To do this, unscrew 
the cover and connecting disc of the unit and then connect the units together. 

 
 
4.) Switching the appliance on and off 
 

First connect the unit properly to the mains socket. Remove the cover plug of the air intake and now turn the 
stepless control dial clockwise until your industrial air purifier starts.  
 

Note: 

Please note that the industrial air cleaner starts immediately at the highest level. Should you continue to turn 

the control dial clockwise, you will increasingly reduce the performance (air flow rate). 

 
 
5.) Strongest operating level (MAX) 

 
We recommend that you initially run the industrial air purifier at full power to sufficiently clean the affected room or 
area. As time goes by, you can decide whether a lower operating level is sufficient for you. 
 
 

6.) Reset button 

 

Use the reset button in the event of technical difficulties (e.g. motor runs out of round) to disconnect your air purifier 
from the power supply in the event of any problems (motor problems) and thus protect it from further damage. The 
reset button has no function in normal state/normal operation. 

 
 

7.) Filter change LED 
 

The filter change indicator shows you when the air flow rate of the unit has decreased considerably due to clogged 
filters. Now the coarse dust filter or the HEPA filter in particular should be checked or replaced. The air flow rate is 
measured by a differential pressure switch integrated in the unit. 
 
Large amounts of dust can greatly reduce the lifetime of the filters. If necessary, change the filters in case of heavy 
soiling even before the filter change indicator lights up. 
 

Hint: 

 
Disconnect the mains plug before cleaning/replacing the filters. For best filtration results, we strongly recommend 
that you use only original filters from the manufacturer. 

 

To change the filter, follow the instructions as described earlier in the operating instructions under point 2.). 
 

 
 
 
 
 

Summary of Contents for WDH-AF500B

Page 1: ...duct To ensure that you get a lot of enjoyment from this product here are a few more tips In case of any problems We hope that the appliance meets your expectations If despite the greatest possible ca...

Page 2: ...e without problems Watch out for electricity never walk into or insert objects into the appliance Only qualified personnel or electricians are allowed to open the inside of the unit Protect the unit f...

Page 3: ...l Info Aktobis de Device description 1 Air intake cover plug 6 Carrying handle 2 Air intake 7 Control element 3 Buckles 8 Cover and connecting disc 4 Coarse dust filter 9 Fan motor 5 HEPA filter 10 Ex...

Page 4: ...locking buckles Now remove the coarse dust filter and the HEPA filter Then insert the new filters neatly back into your air purifier When inserting the HEPA filter make sure that it is inserted the ri...

Page 5: ...clockwise you will increasingly reduce the performance air flow rate 5 Strongest operating level MAX We recommend that you initially run the industrial air purifier at full power to sufficiently clean...

Page 6: ...fficiently ventilated place space Technical data Model name WDH AF500B Voltage 220 240V 50Hz Max Power consumption 225 W 1 0 A Max Air circulation 850 m3 h Noise emission Low 45 dB A High 65 dB A Dime...

Page 7: ...incorrect mains voltage or non observance of the assembly instructions Completely or partially dismantled units Conformity The air purifier has been tested and itself and or parts thereof have been ma...

Page 8: ...____________________________ _________________________________________________________ _________________________________________________________ _______________________________________________________...

Reviews: