#4 System Health Verification
As soon as power is applied to the CO unit (and the RT unit
if locally powered), the system automatically starts up. The
front panel indicators show the status of the system (see
Figure 3 and Table 4). If any of the LED’s is not Normal,
AktinoView can be used to determine the source of the
problem.
AktinoView main status screen shows an overview of the
system. Performance monitoring for DS3, MSPAN, and
PAIRS is available through the menu tabs. Current system
alarms (see Table 3) are displayed on the main status screen.
Alarm history and logs are available through the menu tabs.
Table 3 Common Alarms (displayed by AktinoView)
Alarm Fault
Troubleshooting
DS3 LOS
Check DS3 input connection
DS3 AIS
DS3 input is receiving AIS
DS3 LOF
Check DS3 framing configuration
DS3 RAI
DS3 input receiving RAI
MSPAN LOS
MultiPair Span pairs are down, check pairs
MSPAN Capacity
MultiPair Span capacity below configured
rate; increase number of pairs or decrease
system margin or reduce rate. Check Pairs
PM to ensure proper operation.
Pair LOS
Pair is connected but not receiving signal,
check Pair PM.
Pair Open Circuit
Pair is not connected
Table 4 Front Panel Indicators
LED Condition
Function
STATUS
Off
Green
Red
Power off
Normal
Card malfunction
FUSE
Off
Red
Unit fuse ok
Unit fuse has blown
ALARM
Solid green
Solid yellow
Solid red
Normal
Minor Alarm active
Critical or Major Alarm active
DS3
STATUS
Solid green
Solid yellow
Solid red
Normal
Network or Customer AIS
Network or Customer LOS
MULTIPAIR
SPAN
STATUS
Solid green
Solid yellow
Solid red
Normal
Minor Alarm
Critical or Major Alarm
PAIR
STATUS
Off
Solid green
Flashing green
Solid red
Pair is disabled
Pair is up
Pair is acquiring
Pair LOS/Open circuit/Short
BAT A,
BAT B
Off
Solid green
External DC power has not been
applied
External DC power is present
FAN ALM
Solid green
Solid yellow
Flashing red
Fan status normal
One fan has failed
More than one fan has failed
FUS
E
ST
AT
US
ALAR
M
MU
LT
I P
AIR
DS
3
STATUS
PAIR STATUS
2
1
3
4
5
6
7
14
13
11
10
12
8
9
CRAFT
ACO
FAN
ALM
BAT B
BAT A
AK100F
AK301C
CO DS3
SP
AN
Extraction
handle
Extraction
handle
FU
S
E
ST
AT
U
S
A
LAR
M
M
U
LT
I PAIR
DS
3
STATUS
PAIR STATUS
2
1
3
4
5
6
7
14
13
11
10
12
8
9
SPAN
ACO
ALM
FAN
BAT B
BAT A
F
Fan module
Replaceable
Filter
Wrist strap
grounding
connection
point
Alarm Cutoff
Button
Figure 3 AK3000 Family Front Panel