Display: LCD 3999 counts Updates 2-3/sec
Ranging method: Auto range mode
Polarity indication: “
” display for negative
polarity
Overrange indication: LCD will display “OL”
Low battery: “
” will appears on LCD
Jaw capability: 40mm,Max conductor size
Power: Battery1.5V
u
3
Size AAA
Size: 225mm×86mm×32mm
Weight: Approx. 330g
Operating: 5
to
35
Storage temperature:
10
to 50
DC VOLTAGE
Range
Resolution
Accuracy
400mV 0.1mV
4V 1mV
40V 10mV
400V 0.1V
r
᧤
0.8%+5
᧥
1000V 1V
r
᧤
1.0%+5
᧥
Input Impedance: 10M
:
Overload Protection: 1000V DC or 700V AC RMS
AC VOLTAGE
Range
Resolution
Accuracy
4V/50Hz 1mV