120501
STYLE 3600 SWITCH INTERFACE TRANSMITTER
INSTALLATION AND OPERATING INSTRUCTIONS
The following is intended to provide the basic instructions for installation and operation of the Switch Interface Transmit-
ter (SIT), and to assist in attaining the best possible performance from the unit. Read and understand these operating
instructions before use.
TOOLS REQUIRED
• Wire Cutters
• Wire Crimpers (Deutsch)
• Wire Strippers
PRODUCT WARNINGS
WARNING: For fire fighting use only by trained fire fighters.
WARNING: Although the enclosures for the SIT is water-resistant, it is important to keep water out of the enclosure.
Prolonged exposure to water will cause damage.
WARNING: Replace the identification tags if they should become worn or damaged.
WARNING: The SIT will not operate without a Receiver installed to logic box.
PRODUCT SPECIFICATIONS
Handheld Controller
• Input power
12 or 24 volt DC
• Output power
Meets FCC part 15 requirement for license free operation
• SIT dimensions
5 1⁄4” x 4 5⁄8” x 13⁄8”
• SIT weight
1⁄2 lb
• Operating temperature range
-40°F to 140°F (-40°C to 60°C)
• SIT power
100 mW
• Operating Frequency
2.4GHz or 900MHz (see label for frequency)
• FCC ID
OUR-XBEE
• Security Code
64 bit code from serial number of module
• Range
500 ft
NOTE: Enclosing the SIT in a compartment or behind the pump panel will reduce
the effective range.
!
!
!
!