![AKM AKD4558-A User Manual Download Page 5](http://html1.mh-extra.com/html/akm/akd4558-a/akd4558-a_user-manual_2886271005.webp)
[AKD4558-A]
<KM116602>
2015/04
[1] Power supply line settings
(1-1) Power supply settings : Used the regulator (T1,T2,T3) <Default>
Set up the power supplied lines.
* Each supply line should be distributed from the power supply unit.
Name
Color
Setting (Typ)
Function
Comments
Default Settings
J700
+12V
Red
+12V
Regulator power supply
Should always be connected
+12V
J701
AVDD1
Red
+3.3V
AK4558 AVDD
3.3V regulator is used
(JP700=1pin-2pin short) by
default, when jack is used
(JP700=2pin-3pin short)
REG :
(JP700=1pin-2pin
short)
J702
TVDD
Red
+1.8 / +3.3V/
AK4558 TVDD, Logic
IC power supply
1.8V regulator is used
(JP702=1pin-2pin short and
JP701=REG1.8V) by default,
when 3.3V regulator is used
(JP702=1pin-2pin short and
JP701=REG3.3V), when jack
is used (JP702=2pin-3pin
short)
REG (1.8V) :
(JP702=1pin-2pin
short and
JP701=REG1.8V)
J703
VDD18
Yellow
+1.8V
AK4558 VDD18
1.8V regulator is used
(JP703=1pin-2pin short and
JP100=short) by default,
when LDO of AK4558 is
used (JP100=open), when
jack is used (JP703=2pin-3pin
short and JP100=short)
REG :
(JP703=1pin-2pin
short and
JP100=short)
J704
D3.3V
Red
+3.3V
AK4118A 3.3V VDD,
Logic IC power supply
3.3V regulator is used
(JP704=1pin-2pin short) by
default, when jack is used
(JP704=2pin-3pin short)
REG :
(JP704=1pin-2pin
short)
J706
AVSS
Black
0V
Analog ground
Should always be connected
0V
J705
DGND
Black
0V
Digital ground
Should always be connected
0V
Table 1.Power supply line setting (default: used the regulator )
- 5 -