[AKD5366]
<KM073601>
2007/04
- 7 -
Control Software Manual
Set-up of evaluation board and control software
1. Set up the AKD5366 according to the “Evaluation Board Manual”.
2. Connect IBM-AT compatible PC with AKD5366 by 10-line type flat cable (packed with AKD5366). Take care of the
direction of 10pin header. (Please install the driver in the CD-ROM when this control software is used on Windows
2000/XP. Please refer “Installation Manual of Control Software Driver by AKM device control software”. In case of
Windows95/98/ME, this installation is not needed. This control software does not operate on Windows NT.)
3. Insert the CD-ROM labeled “AKD5366 Evaluation Kit” into the CD-ROM drive.
4. Access the CD-ROM drive and double-click the icon of “akd5366.exe” to set up the control program.
5. Please evaluate according to the following.
Operation flow
Keep the following flow.
1. Set up the control program according to explanation above.
2. Click “Port Reset” button.
Explanation of each buttons
1.
[Port
Reset]: Set
up
the
USB interface board (AKDUSBIF-A).
2. [Write default]: Initialize the register of AK5366.
3. [All Write]:
Write all registers that is currently displayed.
4. [Function1]: Dialog to write data by keyboard operation.
5. [Function2]: Dialog to write data by keyboard operation.
6. [Function3]: The sequence of register setting can be set and executed.
7. [Function4]: The sequence that is created on [Function3] can be assigned to buttons and executed.
8. [Function5]: The register setting that is created by [SAVE] function on main window can be assigned to
buttons and executed.
9.
[SAVE]:
Save
the
current
register
setting.
10. [OPEN]:
Write the saved values to all register.
11. [Write]:
Dialog to write data by mouse operation.
Indication of data
Input data is indicated on the register map. Red letter indicates “H” or “1” and blue one indicates “L” or “0”. Blank is the
part that is not defined in the datasheet.