71
g
Technical data
Electrical data in-
put
Electrical data
output
Battery data
Technical data
Environmental
conditions
Standards
Mains voltage
~ 230 V AC, +/- 15 %
Mains frequency
50 / 60 Hz
Mains current
max. 9 A eff.
Mains fuse protection
max. 16 A
Efficiency
max. 96 %
Effective power
max. 1120 W
Power consumption (standby)
max. 2.4 W
Protection class
I (with PE conductor)
Maximum permitted mains impedance at the inter-
face (PCC) to the public grid
None
EMC emission class
B
Marks of conformity
CE
Nominal output voltage
6 V / 12 V / 24 V DC
Output voltage range
2 V - 33.6 V
Output current
35 A at 28.8 V DC
35 A at 14.4 V DC
35 A at 7.2 V DC
Battery return current
< 1 mA
6 V / 12 V / 24 V DC
3 - 350 Ah
Cooling
Convection and fan
Dimensions l x w x h
270 x 168 x 100 mm
Weight (without cable)
2 kg
Operating temperature
-20 °C - +40 °C (>30 °C derating)
Storage temperature
-40 °C - +85 °C
Climate class
B
Degree of protection
IP40
IEC 60068-2-6
Sine oscillations (10 - 150 Hz; 1.5 h
/ axis)
Summary of Contents for vas 5900A
Page 2: ...0 ...
Page 59: ...57 g Resuming charg ing Press the Stop Start key Charging is resumed 1 ...
Page 68: ...66 optionally set permanently to 6 V 12 V or 24 V ...
Page 75: ...73 g ...
Page 76: ......