Akku Power 7S2P Manual Download Page 8

  LED Code Summary 

LED

 

combination

 

LED

 

comb. no. 

Description

Description

 

Action

10

Undervoltage 

Battery voltage is 

too low / completely 

empty

If battery is not charging after 5 minutes and charger is indicating defective 

battery please contact your IDEX Fire & Safety technical service. 

16

Load Overcurrent 

1 (>52A for 5s) 

Current consumption 

between battery and 

tool is temporarely 

too high

Wait until the error code is gone (min. 30s). Check the battery function using 

another tool.

If the error persists with second tool contact your dealer otherwise check the 

first tool to exclude its defect.

17

Load overcurrent 2

(>156A for 160ms) 

Current consumption 

between battery and 

tool is temporarely 

too high

Check battery on another tool and after minimum 30 sec the error should be 

gone.

If the error persists with the second tool contact your dealer otherwise send in 

the first tool for a technical revision.

18

Charge 

overcurrent

Charging current 

too high

Check battery on another charger and after minimum 30 sec the error should 

be gone

If the error persists with the second charger contact your dealer otherwise 

send in the first charger for a technical revision

19

Short circuit

Power consumption 

too high – higher 

than the overload 

current

Be sure that „+ / -“contacts are not directly in contact via conducting materials.  

Wait for at least 30 sec until the error should be gone, then check the battery 

in another tool. 

If the battery error code occurs in second tool please contact your dealer´s 

technical service for assistance.

20

Temperature 

not OK

Cell and FETs 

temperature 

is outisde the 

recommend 

temperature range

First adjust the Cells temperature by disconnecting or stop operating the 

battery in order to let the battery cool down or warm up until it reaches the 

maximum or minimum allowed temperature

Later if the battery is still blocked test the battery in another tool to test if the 

the error persists.

If the battery error code occures in second tool please contact your dealer´s 

technical service for assistance.

7

8

Summary of Contents for 7S2P

Page 1: ...SAFETY INSTRUCTIONS Li ION DT2 Battery 7S3P 25 2V 9 0Ah 226 8Wh 7S2P 25 2V 5 0Ah 126 Wh IDEX Fire Safety www akku power com...

Page 2: ...2 GB 3 8 D 9 14 Please scan for more languages...

Page 3: ...ush or throw the battery pack DO NOT put the battery pack into a microwave or high pressure container Never expose batteries to microwaves or high pressure DO NOT open a battery pack for any reason If...

Page 4: ...ents avoiding contact with other items or conductive materials that may cause damages or short circuits on the pack If this is not guaranteed please reconsider storing location of the battery pack or...

Page 5: ...ent fire explosion may follow depending on the circumstances If a battery burns the vapors can irritate eyes skin and the respiratory tract If chemicals leak follow the instructions below Inhalation C...

Page 6: ...ccurrence and will be displayed until the query button is pressed again The BMS will store the last 3 error codes All possible LED combinations are listed in table 2 to table 7 LED combination LED com...

Page 7: ...of health If the usable capacity of the battery is 60 of the installed capacity Ah the SOH code will be displayed every time the battery comes out of the sleep mode Once the SOH code is shown on the d...

Page 8: ...urrent Charging current too high Check battery on another charger and after minimum 30 sec the error should be gone If the error persists with the second charger contact your dealer otherwise send in...

Page 9: ...he Verformung der Zelle besch digt Der Separator wird durch mechanische Einwirkungen besch digt die z B durch eine Tiefentladung der Zelle verursacht werden Herzlichen Gl ckwunsch D 9 VORSICHTSMASSNAH...

Page 10: ...die Batterie auf sichere Weise zu verwenden d rfen das Batterieladeger t nicht ohne Aufsicht oder Anweisung eines Fachmanns verwenden Beachten Sie unbedingt die minimale und die maximale Lade tempera...

Page 11: ...ktrischer Verwendung die zu einer Aktivierung der Sicherheitsventile und oder einer Ruptur des Akkugeh uses f hrt Abh ngig von den Umst nden kann es zu einem Elektrolyt Austritt oder zu einer Reaktion...

Page 12: ...zeigt Wenn der Akku nicht auf dem Ger t oder auf dem Lader steckt wird der Ladezustand SOC nach Dr cken der LED Taste f r 25 Sek angezeigt Der Ladezustand erlischt nach der angegebenen Zeit oder nach...

Page 13: ...cher alle LEDs f r 1 5 Sek ausgehen Das sollte dem Benutzer helfen einfach und schnell die einzelnen Fehlercodes zu unterscheiden LED Kombination LED Komb Nr Beschreibung 16 berstrom Entladung 1 17 be...

Page 14: ...m ist zu hoch berpr fen Sie den Akku eines anderen Ladeger ts und nach mindestens 30 Sekunden sollte der Fehler behoben sein Wenn der Fehler beim zweiten Ladeger t weiterhin besteht wenden Sie sich an...

Reviews: