Page 33 of 56
Designation Value
Marking
Done
R1
24.9
Red, Yellow, White, Gold, Brown
C1
10 nF
10nJ100
BR1
GBPC3506W
1.
Locate the green 18 AWG stranded wire with a FASTON terminal installed on
one end. Cut it to an overall length of 14”, measured from the far-end of the
FASTON. Remove 1/4” of insulation from the plain end of the green wire. Insert
it into the GWGND eyelet on the Ground Lifter PCB. Insert it from the side with
the bridge rectifier, and solder it on the silk-screen side of the PCB.
2.
Cut a 2” length of black 18 AWG stranded wire. Remove ¼” of insulation from
both ends. Insert one end into the CHGND eyelet on the ground lifter PCB. Insert
it from the side with the bridge rectifier, and solder it on the silk-screen side of the
PCB.
3.
Twist and tin the other end of the wire. Insert it into a #6 lug. Crimp it and solder
the wire to the lug.
Figure 34-Ground Lifter PCB with ground wires connected
AC Power Wiring
1.
Locate the 1 foot long white and black 18 AWG wires with FASTONS on both
ends. Twist the wires together. This minimizes the radiated hum fields.
Figure 35-FASTON connector
2.
Slide the FASTON terminals onto the IEC power connector as shown in Figure
36.
i.
Black wire to L (line) terminal.
ii.
White wire to N (neutral) terminal.
iii.
Don’t connect the G
(ground terminal) yet.
Figure 36-Wiring IEC power connector line and neutral