CAUTION 
Before serving the chassis, read the “X-Ray Radiation Precaution”, “Safety Precaution” and 
“Product Safety Notice” on this page.

 

 

                                                

X-RAY RADIATION PRECAUTION 

 

1.  Excessive high voltage can produce potentially hazardous X-Ray Radiation. To avoid such 

hazards, the high voltage must not be above the specified limit. The normal value of  the high 
voltage of this receiver is 24KV at zero beam current (minimum brightness) under 220V AC 
power source. The high voltage must not, under any circumstances, exceed 30KV. 

 

2.  Each time a receiver requires servicing, the high voltage should be checked following the High 

Voltage Check procedure in this manual. It is recommended the reading of the high voltage 
should be recorded as a part of the service record. It is important to use an accurate and reliable 
high voltage meter. 

 

3.  The primary source of X-Ray Radiation in this TV receiver is the picture tube. For continued 

X-Ray Radiation protection, the replacement tube must be exactly the same type tube as 
specified in the part list. 

 

4.  Some parts in this receiver have special safety – related characteristics for X-Ray Radiation 

protection. For continued safety, parts replacement should be undertaken only after referring to 
the Product Safety Notice. 

 

SAFETY PRECAUTION 

 

Warning: Service should not be attempted by anyone unfamiliar with necessary precaution on this 
receiver. The following are the necessary precautions observed before servicing this chassis. 
 

1.  Since the power supply circuit of this receiver is directly connected to the AC power line, an 

isolation transformer should be used during any dynamic service to avoid possible shock hazard. 

 
2.  Always discharge the picture tube anode to the CRT conductive coating before handling the 

picture tube. The picture tube is highly evacuated and if broken, glass fragment will be violently 
expelled. Use shatter proof goggles and keep picture tube away from the unprotected body while 
handling. 

 

3.  When replacing a chassis in the cabinet, always be certain that all the protective devices are put 

back in place, such as: non-metallic control knobs, insulating covers, shields, isolation 
resistor-capacitor network etc. 

 

4.  When replacing parts or circuit boards, disconnect the power cord. 

 

   

5.  When replacing a high voltage resistor (Metal oxide film resistor) on circuit board, keep the 

resistor 10mm (1/2in.)away from circuit board. 

6.  Connection wires must be kept away from components with high voltage or high temperature. 
7.  If any fuse in this TV receiver is blow, replace it with the FUSE specified in the chassis part list. 
8.  The receiver is designed to operate with 220V(50/60Hz) AC mains. 

 
 

 

 
 

Summary of Contents for CT-25NI9AN

Page 1: ...C C Co o ol l lo o ou u ur r r T T TV V V S S Se e er r rv v vi i ic c ce e e M M Ma a an n nu u ua a al l l...

Page 2: ...Model No CT 25NI9AN Version 1 0 2 CHASSIS 5N11 MODEL CT 25NI9AN...

Page 3: ...Model No CT 25NI9AN Version 1 0 3 CONTENTS 1 SPECIFICATIONS 4 2 X RAY RADIATION PRECAUTION 5 3 SAFETY PRECAUTION 5 4 PRODUCT SAFETY NOTICE 5 5 ALIGNMENT INSTRUCTION 6 6 SCHEMATIC DIAGRAM 14...

Page 4: ...Picture Tube 64 cm 25 diagonal Ext Antenna 75 Ohm Coaxial Cable Ext In Out Audio Video in out Speakers 8W x 2 Volts A AC100 260V 50 60Hz R N CP AC 150 260V 50 60Hz Power Consumption 25 120W Dimension...

Page 5: ...after referring to the Product Safety Notice SAFETY PRECAUTION Warning Service should not be attempted by anyone unfamiliar with necessary precaution on this receiver The following are the necessary...

Page 6: ...L key and VOL key on the control board at the same time and switch on power switch then go to the function set menu After TV is on press factory key See Note 1 twin then go to the function set menu 1...

Page 7: ...ance test signal b Set picture MILD mode c Insert the special plug into CN002 press adjustment key which belongs to white balance adjustment equipment and go to auto white balance adjustment d After a...

Page 8: ...itialized with default data after main power switch is on Most parameters are free alignment after initialized only need adjust the several parameters of function set parameter and system parameter ad...

Page 9: ...and select Position Menu as below V POSITION for adjust vertical position 00 to 07 H POSITION for adjust Horizontal position 00 to 1F V EHT for adjust vertical shape 00 to 0F H EHT for adjust Horizont...

Page 10: ...e zero M decoder ON OFF I decoder ON OFF BG decoder ON OFF Reserved for internal using must be zero OPTION 3 Sopdata3 x x x x x x x x Tuner LNA Hold on when no signal VIF VCO 38MHz or 38 9MHz selectio...

Page 11: ...tion yoke and pull the deflection yoke towards you 7 Enter into ADJUST MENU set the values of C R C G C B to 00 8 Adjust the purity magnets so that green field is obtained at the center of the screen...

Page 12: ...Receive colour pattern signal and the system colour PAL SECAM NTSC Check the power main on off switch brightness volume colour contrast and tint The picture quality must not have colour noise unbalan...

Page 13: ...HIGH POTENTIAL TESTING 1 Set the mega meter is set in position Insulation tester 2 Set the meter to DC500V 3 Use the meter probe onto the tuner body and the power cord on connector socket 4 Switch on...

Page 14: ...0 0 1 0 0 1 1 2 0 3 3 4 5 1 1 4 4 0 6 6 6 6 00 00 1 23 45 00 00 55 55 16 74 14 38 79 2 0 4 38 38 38 14 1 14 74 12 2 2 2 2...

Reviews: