2 Beeper
a. When PCB becomes active or receives the signal from the remote controller, the beeper will
beep.
3 Indication lamps
a. It flashes when defrosting begin.
4 Press the AUTO button a time, the machine runs in AUTO mode, indoor motor runs in low speed,
fresh air function is not active, press again the machine stops.
5 Fresh air function.
a. There are two fresh air modes.
Fresh air 2
i. Fresh air motor will work 1 hour, then rest 1 hour, then cycle again.
Fresh air 1
ii. Press the button AIR on the remote controller to select fresh air 1 function, the swing motor
keeps running till you give a signal to change it.
6 Automatic fan speed.
a. In cooling mode, if T indoor > T set + 5
o
C high speed
T indoor > or = T set +3
o
C middle speed
T indoor > or = T set + 1
o
C low speed
b. In dehumidify mode, if T indoor > or = T set + 5
o
C high speed
T indoor > or = T set + 2
o
C low speed
SLEEP mode
1 In cooling or dehumidifying mode, 1 hour after you set the sleep timer, T set will add 1
o
C
automatically, another 1 hour, another 1 will be added.
2 In heating mode, 1 hour after you preset the sleep timer, T set will lower 1
o
C automatically, another
1 hour, another 1
o
C will be lowered.