20
Model No: AC-S10CG
Version 1.0
Other controls
1 SWING mode
a. When it is active, the louver returns to position O, close the air outlet.
b. When machine works, it turns to the max. Air output position D, then returns back to
position L to stand by (position L is the horizontal place mentioned before).
c. In swing state, the louver swings between position L and position D.
d. When the machine is switched off, it is back to position O.
e. When the machine is running and the swing is off, the louver stops at position E.
O
L
E
D
2 Beeper
a. When PCB becomes active or receives the signal from the remote controller , the
beeper will beep.
3 Indication lams
a. It flashes when defrosting begin.
4 Press the AUTO button a time, the machine runs in AUTO mode, indoor motor runs in low
speed, fresh air function is not active, press again the machine stops.
5 Digital tube display
a. the digital tube displays the setting temperature (the range is16~30
o
C) when the
machine is running
b. The digital tube displays the setting time (the range is 1~24 hours) for 5 seconds
when remote controller sets timer of on/off. Then come back to display the setting
time; timer displays “—“, it means that timer setting is canceled.
c. Light button: when remote controller(Y512) sends light signal, the digital tube is
lighted for 2~4 seconds then turns off.
6 Fresh air function.
a. There are two fresh air modes.
i. fresh air 2 === fresh air motor will work 1 hour, then rest 1 hour, then cycle again.
ii. fresh air 1 === press the button AIR on the remote controller to select fresh air 1
function, the swing motor keeps running till you give a signal to change it.