![akira 14TDS3/VE Service Manual Download Page 17](http://html1.mh-extra.com/html/akira/14tds3-ve/14tds3-ve_service-manual_2886014017.webp)
Model No: 14TDS3Ve
Version 1.0
Observe if there is sine wave on t he pin31
or pin32 of N701 with an oscilloscope
No
Check Z701,N701
Check the voltage on the pin33 of N701
Yes
Check N701
4.98V
Check the voltage on the emitter of V705
<4.98V
Check R741
Check the voltage on the positive pole of VD 704
4.98V
<4.98V
<3.6V
Check R753,VD704
=3.6V
Check R754, V705, R752
Check the voltage on the positive pole of C566
Check N705
Check alternant voltage
on secondary coil of T502
<7V
<5V
Check T501
Check T501,VD556,C556
>5V
N701 does not work
The voltage on the pin42 of N701
5V
<5V
17