7 Specifications

7.1 Microphone

7.2 Remote Control Unit

Type:

1-inch dual-diaphragm, true condenser pressure-
gradient microphone

Polar patterns:

omnidirectional, cardioid, figure eight plus six 
intermediate patterns (selectable on Remote 
Control Unit)

Open-circuit sensitivity 
at 1kHz (cardioid):

20 mV/Pa (-34 dBV ±3 dB)

Frequency range:

20 Hz to 20 kHz (see frequency response graphs)

Impedance:

≤ 200 ohms

Recommended load impedance:

≥ 1000 ohms

Equivalent noise level 
to IEC 60268-4 (A-weighted):

16 dB-A

Signal/noise ratio re 1 Pa (A-weighted): 78 dB

Max. SPL:

135 / 155 dB SPL (0 / -20 dB)

Preattenuation pad:

-20 dB (switchable on Remote Control Unit)

Bass cut filter slope:

12 dB/octave, 80 Hz 
(switchable on Remote Control Unit)

Environment:

temperature: -10°C to +60°C
R.H.: 80% (+25°C)

Powering:

via Remote Control Unit only

Connector:

dedicated 7-pin male XLR

Dimensions:

53 dia. x 212 mm high / 2 x 8.3 in.

Net weight:

870 g / 1.9 lbs.

Audio/control input:

dedicated 7-pin female XLR connector

Audio output:

standard 3-pin male XLR connector, 
balanced, pin 2 hot

Polar pattern selector:

9-position detented rotary switch

Bass cut filter switch:

2-position toggle switch

Preattenuation switch:

2-position toggle switch

Power voltage:

210-240 VAC or 110-120 VAC, selectable

Primary fuse:

125 mA / 250 V slow-blow

Summary of Contents for PERCEPTION820 TUBE

Page 1: ...USER INSTRUCTIONS p 2 Please read the manual before using the equipment MODE D EMPLOI p 20 Veuillez lire cette notice avant d utiliser le syst me PERCEPTION820TUBE...

Page 2: ...Down 8 4 Using the Microphone 9 4 1 Introduction 9 4 2 Bass Cut Filter 9 4 3 Preattenuation Pad 10 4 4 Hints on Microphone Placement 10 4 4 1 Lead Vocals 10 4 4 2 Choir Backing Vocals 10 4 4 3 Trumpe...

Page 3: ...l not use the equipment for a long period of time disconnect the equipment from power Please note that the equipment will not be fully isolated from power when you set the power switch to OFF 8 Discon...

Page 4: ...ngs a degree of warmth and musicality that is difficult to achieve with solid state microphones The microphone incorporates a carefully selected ECC 83 tube If the tube needs replacing you may alterna...

Page 5: ...y mixer input stages etc D Bass cut switch This toggle switch lets you reduce low end distortion caused by foot fall or wind noise etc The bass cut filter also minimizes the proximity effect that clos...

Page 6: ...J GROUND LIFT This pushbutton switch allows you to remove hum caused by ground loops To open the chassis ground connection press the GROUND LIFT button OUT LIFT po sition To restore the chassis groun...

Page 7: ...he rear panel to the correct position as shown in Table 1 below 3 Referring to Table 1 above use the correct power cord to connect the Remote Control Unit to a grounded power outlet When on tour you m...

Page 8: ...ide the microphone to heat up properly 1 Set the power switch on the Remote Control Unit rear panel to 0 The front panel POWER LED will go out 2 Wait for five minutes to allow the tube to cool down to...

Page 9: ...nt Keep the microphone dry Moisture from blowing or singing directly at the capsule from a short distance or extremely high humidity may cause the microphone to start crack ling or go very quiet due t...

Page 10: ...other It is also a good choice for cymbal overhead miking Every instrument radiates its sound in a specific way Therefore to get the best sound do not hesitate to experiment with microphone placement...

Page 11: ...chnique 1 Refer to section 4 4 1 Lead Vocals above If you have enough tracks avail able we recommend overdub bing each voice separately Backing vocals technique 2 If you use a separate micro phone for...

Page 12: ...om Electric bass Use the same technique as for the electric guitar You can use a DI box to add the direct signal of the line output on the bass amp to the microphone signal Solo violin Set the polar p...

Page 13: ...s above Cello technique 2 Use a close in microphone as in technique 1 above plus a distant microphone Set the level of the close in microphone approx 20 dB lower than the distant mic level We recommen...

Page 14: ...PERCEPTION 820 TUBE or a stereo pair see section 4 4 2 Choir at the middle strings from a height of 5 to 7 feet 1 5 to 2 m For a rock pop sound place two microhones roughly 8 to 16 in 20 to 40 cm abov...

Page 15: ...the drummer s head Set each microphone to car dioid or omnidirectional mode Use little or no EQ This tech nique will pick up the entire kit delivering a highly natural sound Cymbals To record cymbals...

Page 16: ...nt inside the Remote Control Unit To avoid elec tric shock injury and fire UNDER ALL CIRCUMSTANCES disconnect the power cord from the Remote Control Unit before replacing a fuse To avoid damage replac...

Page 17: ...red level 3 Connect microphone to mixer or recording device 4 Check cable connectors for secure seat 5 Check cables and replace damaged cable s 6 Check POWER LED Switch power to Remote Control Unit on...

Page 18: ...weighted 78 dB Max SPL 135 155 dB SPL 0 20 dB Preattenuation pad 20 dB switchable on Remote Control Unit Bass cut filter slope 12 dB octave 80 Hz switchable on Remote Control Unit Environment tempera...

Page 19: ...19 PERCEPTION 820 TUBE 7 Specifications Frequency Response Polar Diagram Omni directional Cardioid Figure Eight...

Page 20: ...com Dieses Produkt entspricht den in der Konformit tserkl rung angegebenen Normen Sie k n nen die Konformit tserkl rung auf http www akg com oder per E Mail an sales akg com anfordern Questo prodotto...

Page 21: ...39 PERCEPTION 820 TUBE Notes Notes...

Page 22: ...es Fones de ouvido Microfones s fios Fones de ouvido s fios Microfones de cabe a Componentes ac sticos Technische nderungen vorbehalten Specifications subject to change without notice Ces caract risti...

Page 23: ...dable tube microphones the Perception 820 Tube delivers real tube sound quality The Perception 820 Tube s features are endless The dual one inch True Condenser Large Diaphragm capsule delivers a clear...

Page 24: ...00 Ohms Equivalent noise level 16 dB A Signal Noise ratio 78 dB A weighted Maximum SPL 135 155 dB SPL 0 20 dB Pad Attenuation Pad 20 dB switchable on remote control unit Low cut filter 80 Hz 12 dB oct...

Page 25: ...Perception 820 Tube 3101H00100 AKG Service Department Lemb ckgasse 21 25 A 1230 Wien Austria Tel 431 86654 0 FAX 431 86654 1514 e mail service akg com 10 09 7 13 2 3 4 1 5 6 12 1 8 11 10 9 1 2...

Page 26: ...kabel Rubber band 5 3101M71010 2 Gummiband Tube 6 3101M62010 1 R hre PCB assy microphone 7 3101M61010 1 Mikrofonprint kompl Switch 8 3101M54010 2 Schalter Switch assy with knob 9 3101M52010 1 Schalter...

Reviews: