background image

3

AKG PERCEPTION 420

1 Precaution/Unpacking

1.1 Precaution

Please make sure that the piece of equipment
your microphone will be connected to fulfills
the safety regulations in force in your country
and is fitted with a ground lead.

1.2 Unpacking

Check that the packaging contains all of the items
listed below:

• Microphone
• Spider suspension
• Carrying case
• Mini poster

Should any item be missing, please contact your
AKG dealer.

2 Description

2.1 Introduction

Thank you for purchasing an AKG product. This
Manual contains important instructions for setting
up and operating your equipment. Please take a
few minutes to

read the instructions below care-

fully before operating the equipment

and keep

the Manual for future reference. Have fun and
impress your audience!
The PERCEPTION 420 is a heavy-duty, rugged true
condenser microphone built to the same strict qual-
ity standards as all other AKG products.
Designed on the basis of AKG’s decades of know-
how and feedback from sound engineers around
the world using AKG studio microphones every day,
this general-purpose 1-inch dual large-diaphragm
microphone brings AKG studio quality to the worlds
of recording, live sound, and broadcasting.

2.2 Features

Selectable polar patterns:

The microphone’s

transducer uses a dual diaphragm. This sophis-
ticated technology allows you to select the opti-
mum polar pattern (cardioid, omnidirectional, or
figure eight) for every application.

Gold-sputtered diaphragm:

The diaphragm is

made of a plastic foil that is gold-sputtered on
one side only to prevent shorting to the back
electrode even at extremely high sound pres-
sure levels.

All-metal body:

The all-metal body adds to the

rejection of RF interference so you can use the
microphone near transmitter stations and along
with wireless microphones or other communi-
cations equipment. The extremely rugged,
heavy body and sturdy front grill protect the
microphone from damage from tough handling
on stage.

High

headroom,

minimum

distortion:

Capable of handling sound pressure levels up
to 155 dB without introducing perceptible dis-

L

!

Summary of Contents for PERCEPTION 420

Page 1: ...PERCEPTION 420 User Instructions p 2 Please read the manual before using the equipment Mode d emploi p 14 Veuillez lire cette notice avant d utiliser le syst me...

Page 2: ...ccessories 5 3 Interfacing 6 3 1 General 6 3 2 Pinout 6 3 3 Connecting the Microphone 6 4 Using Your Microphone 7 4 1 General Hints 7 4 2 Selecting Polar Patterns 8 Page 5 Cleaning 8 6 Troubleshooting...

Page 3: ...s decades of know how and feedback from sound engineers around the world using AKG studio microphones every day this general purpose 1 inch dual large diaphragm microphone brings AKG studio quality to...

Page 4: ...y 20 dB for distortion free close in recording The preattenuation pad prevents the microphone s output level partic ularly at low frequencies from overloading the miniature transformers used in many m...

Page 5: ...ERCEPTION 420 causes in any unidirectional microphone The filter rolls off at 12 dB octave from 300 Hz downward 2 3 Optional Accessories PF 80 studio pop screen ST 305 floor stand W 4000 external wind...

Page 6: ...r supply 3 2 Pinout The microphone provides a balanced output on a 3 pin male XLR connector Pin 1 ground Pin 2 hot Pin 3 cold 3 3 Connecting the Microphone Refer to fig 3 below 1 Use an XLR cable to c...

Page 7: ...optional PF 80 pop screen from AKG between the microphone and vocalist instrument Keep the microphone dry Moisture from blowing or singing directly at the capsule from a short distance or extremely h...

Page 8: ...hand setting The micro phone will pick up sounds arriving from the front and rear with equal sensitivity Use this mode to mic up the side signal in M S stereo recording or to record two sound sources...

Page 9: ...lose to sound source 3 Microphone sensitivity set too high 1 Switch power to mixer or amplifier on 2 Set channel or master fader on mixer or volume control on amplifier to desired level 3 Connect micr...

Page 10: ...10 Crackling noises or low output Partial short circuits due to excessive humidity Place microphone in warm dry room and allow to dry Problem Possible Cause Remedy AKG PERCEPTION 420 6 Troubleshooting...

Page 11: ...ghted 78 dB Max SPL for 0 5 THD 135 155 dB SPL 0 20 dB Preattenuation pad 20 dB switchable Bass cut filter slope 12 dB octave 300 Hz Environment temperature 10 C to 60 C R H 80 25 C Powering 48 V 4 V...

Page 12: ...12 Frequency Response cardioid Cardioid Polar Diagram Frequency Response omnidirectional Omnidirectional Polar Diagram AKG PERCEPTION 420 7 Specifications...

Page 13: ...13 AKG PERCEPTION 420 Frequency Response figure eight Figure Eight Polar Diagram 7 Specifications...

Page 14: ...z prendre connaissance en consultant le site http www akg com ou en adressant un e mail sales akg com Italiano Questo prodotto corrisponde alle norme elencate nella dichiarazione di conformit che disp...

Page 15: ...ac sticos Microfones Fones de ouvido Microfones s fios Fones de ouvido s fios Microfones de cabe a Componentes ac sticos Technische nderungen vorbehalten Specifications subject to change without notic...

Reviews: