background image

Important!

Note:

3.1 Data Connections

3.1.1 Direct Connection 

to the Computer

3.1.2 Connecting to the

Computer via a Switch

3.1.3 Connecting AKG devices

3.2 Connecting to Power

3.3 Powering Up/Down

3.4 Configuring the Computer

Important!

Important!

Important!

8

Prior to setting up the unit, check that the AC mains voltage stated on the included power
supply is identical to the AC mains voltage available where you will use your system.
Using the power supply with a different AC voltage may cause damage to the unit.

Although the equipment will operate on both 10-Mbit and 100-Mbit networks, we recommend using
a 100-Mbit network.

1. Use a crossover Ethernet cable to connect the HUB 4000 Q to a computer.
2. Connect the HiQnet LINK socket on the HUB 4000 Q to a network input on the computer or network

card. (For details refer to the manual of your computer.)

A single HUB 4000 Q allows you to control up to eight AKG devices from a computer. You can use one
or more commercial switches (Ethernet hubs, routers, etc.) to daisy-chain several HUB 4000 Qs and con-
trol the entire setup from the computer.

1. Connect the switch to the computer referring to the manual(s) of the swiwtch and/or computer.
2. Plug a straight-through network cable into the HiQnet LINK socket of each HUB 4000 Q.
3. Plug the other end of each network cable to an unused output on (one of) your switch.

1. Be sure 

not to use any cables other than the supplied data cables

with RJ 11 connectors.

2. Connect the data port on each AKG device to one of the AKG NETWORK DEVICES sockets nos. 1 to

8 on the HUB 4000 Q rear panel.

1.

Check that the AC mains voltage stated on the included power supply is identical to the AC
mains voltage available where you will use your system. Using the power supply with a differ-
ent AC voltage may cause damage to the unit.

2. Plug the DC cable on the included power supply into the 12 V/500 mA socket on the HUB 4000 Q rear

panel and screw down the DC connector.

3. Plug the power cable on the power supply into a convenient power outlet.

1. To switch power to the unit on, press the ON/OFF key.

The status LED next to the ON/OFF key will be lit, the blue DATA TRANSFER TO AKG DEVICE LEDs
will illuminate starting from the center and extinguish to indicate the unit is initialized and ready to
operate.

2. To switch power to the unit off, press the ON/OFF key again.

1. Make sure that a functioning network card is installed in your computer.
2. Install System Architect™ on your computer by following the installation instructions that come with

in the download.

3. Make all data and network connections.
4. Connect all AKG devices connected to your network to power.
5. Switch power to all AKG devices on your network on.

6. Turn off all firewall and/or proxy software that may be running on your computer. This is

absolutely necessary because this type of software may interfere with data communications
within the HiQnet™ network.

7. Start System Architect™.

System Architect™ and the HUB 4000 Q support DHCP (Dynamic Host configuration Protocol). This
means that System Architect™ will automatically assign an unambiguous TCP/IP address to the net-
work card and to each AKG device on your network. Therefore, you do not need to assign address-
es manually.

1. Disconnect the power supply from the power outlet.

2. Use a cloth moistened (not wet!) with water to clean the surfaces of the equipment.

Never use caustic or scouring cleaners or cleaning agents containing alcohol or solvents

since these may damage the enamel or plastic parts.

3 Setting Up

HUB 4000 Q

4 Cleaning

5900_HUB4000_cb  07.12.2005  11:22 Uhr  Seite 8

Summary of Contents for HUB 4000 Q

Page 1: ...nt Mode d emploi p 10 Veuillez lire cette notice avant d utiliser le syst me Istruzioni per l uso p 14 Prima di utilizzare l apparecchio leggere il manuale Modo de empleo p 18 Sirvase leer el manual a...

Page 2: ...ce these may damage the enamel and plastic parts 11 Use the equipment for the applications described in this manual only AKG cannot accept any liabili ty for damages resulting from improper handling o...

Page 3: ...ted AKG device LED flashing slowly approx once every 3 seconds There is a communication problem between the assigned data port on the HUB 4000 Q and the connected AKG device hard or software error def...

Page 4: ...he AC mains voltage available where you will use your system Using the power supply with a differ ent AC voltage may cause damage to the unit 2 Plug the DC cable on the included power supply into the...

Page 5: ...connected to HUB 4000 Q and or power outlet HUB 4000 Q is not connected to compu ter network card switch No AKG device connected 1 Data cable s disconnected during data transfer 2 Data cable s defect...

Page 6: ...26 HUB 4000 Q Fig 3 A B C Fig 3 1 A C B D Fig 3 2 D...

Page 7: ...kr fur og nnur kv i 1999 5 reglu Ev pusambandsins H gt er a panta fr tt eintak af sta alyfirl singunni vefs unni http www akg com e a me v a hafa samband vi sales akg com Firma AKG Acoustics GmbH apli...

Page 8: ...Componenti acustici Micr fonos Auriculares Micr fonos inal mbricos Auriculares inal mbricos Auriculares con micr fono Componentes ac sticos Microfones Fones de ouvido Microfones s fios Fones de ouvido...

Reviews: