AKG C480 B ULS Service Manual Download Page 2

 

 

SERVICE

 

MANUAL

 

/

 

#

 

2180Z00

010

/

150

 

/

 

10/2016 

 

 

AKG

 

CUSTOMER

 

SERVICE

 

DEPARTMENT

 

/ Laxenburger Straße 254 / 1230 Vienna, Austria   

TEL: +43 1 866 54 -0 / FAX: +43 1 866 54-1514 / [email protected]  / 

www.akg.com

 

  2/4 

 

 

 

Technical Data:                                                       Technische Daten: 

 

Transmission range 

 

 

10...30.000 Hz                                            Übertragungsbereich 

High pass filter   

 

 

70 Hz, 150 Hz - 3 dB, 12 dB/Octave                         Hochpassfilter 

Open loop gain @ 1 kHz   

 

- 1 dB                                     Leerlaufübertragungsfaktor,@ 1kHz 

Input Impedance @ 1 kHz  

            > 5 GOhm//1pF                                   Eingangsimpedanz, @ 1kHz 

Output Impedance (20...20 kHz)   

< 150 Ohms  

                        Ausgangsimpedanz (20...20 kHz) 

Permissable load   

 

 

0...

  

                                                      Zulässiger Abschluss 

Equivalent noise level (+ CK 61)   

 

 

 

 

  Ersatzgeräuschpegel (+ CK 61) 

in Pos.: 0 dB:  

 

 

 

< 18 db (DIN 45405, CCIR 468-2)  

 

   in Pos.: 0 dB 

Polarizing Voltage 

 

 

+ 62 V   

 

 

 

   Polarisationsspannung 

Current consumption 

 

 

< 2mA   

 

   

                        Stromaufnahme 

Climate conditions 

 

 

- 20°...+ 60° C                                              Temperaturbereich 

Rel. humidity  

 

 

 

99% @ 20°C, 95% @ +60°C  

                       Relative Feuchte 

Net weight 

 

 

 

98,5 g                                                                 Gewicht (netto) 

 

S/N ratio according to EN 50082-1 part 1, evaluation criterion A:  17 dbA @ 1 Pa, 1 kHz with CK 61 

Störabstand gemäß EN 50082-1 Teil 1, bei Bewertungskriterium A: 17 dbA, bezog. auf 1 Pa, 1 kHz, mit CK 61 

 

**************** 

 
 

Repair Hints: 
 

After  changing  parts  1.1,  1.6  or  1.7 
residue  from  soldering  has  to  be 
carefully  removed.  Cleaning  should    be 
done  with  a  hard  brush  and  pure,  clean 
alcohol 

(Propanol). 

After 

cleaning, 

boards  should  be  heated  to  +  50°  C  for 
at  least  one  hour  to  let  any  humidity 
completely  evaporate.  Then  all  solder 
points  and  components  around  the 
contact  assembly  have  to  be  carefully 
covered  with  polyurethane  laquer  such 
as  CRC  Urethane  71.  These  repairs 
should  be  carried  out  by  trained  and 
experienced  technicians  only.  Otherwise 
we  recommend  to  return  the  complete 
microphone    to  AKG  Vienna  for 
refurbishing. 

Reparaturhinweis: 

 

Nach dem Tausch der Teile 1.1, 1.6 oder 
1.7  sind  alle  Lötrückstände  sorgfältig  zu 
entfernen.  Verwenden  Sie  dazu  reinen 
hochprozentigen 

Alkohol 

(Propanol). 

Nach  dem  Reinigen  sollte  der  Print 
mindestens  eine  Stunde  bei  +  50°  C 
ausgeheizt  werden,  damit  die  gesamte 
Restfeuchte 

verdampfen 

kann. 

Anschließend  müssen  alle  Lötstellen  und 
Bauteile  im  Bereich  des  Kontaktträgers 
sorgfältig  mit  Polyurethanlack  (z.B.  CRC 
Urethan  71)  abgedeckt  werden.  Diese 
Reparaturen  sollte  nur  ein  erfahrener 
Techniker 

durchführen. 

Anderenfalls 

empfehlen  wir,  das  Mikrofon  an  AKG 
Wien zur Reparatur einzusenden. 

 
 
 
 
 
 
 
 
 

 

 