C535 EB MANUAL
27
DESCRIPTION
Use a small screwdriver or similar object to adjust the desired
switch position.
Figure 1: Mode switch
The switch offers four different positions:
1
0 dB
JVUKLUZLYTPJYVWOVULV\[W\[SL]LST=7HÅH[V]LY
-
load limit: 130 dB SPL.
2
0 dB
JVUKLUZLYTPJYVWOVULSL]LSHZHIV]L^P[OIHZZJ\[ÄS[LY
below 100 Hz slope: 12 dB/octave.
Applications: mainly instrumental recordings, for reducing
unwanted low frequency structureborne noise.
3
-14 dB
attenuation of –14 dB, dynamic microphone output level,
ÅH[V]LYSVHKSPTP[!K):73
Applications: recording high sound level instruments, or
WYL]LU[PVUVMV]LYSVHKPUNVMTP_LYVYHTWSPÄLYPUW\[Z^OPJO
are adjusted for dynamic microphones.
1
2
4
3