Specifications  

5

 

Specifications 

Electrical working principle: 

Condenser microphone, self-polarised 

Acoustic working principle: 

Pressure gradient receiver 

Polar pattern: 

Cardioid 

Frequency range: 

20 to 20,000 Hz ± 2 dB from nominal 
frequency curve 

Field open loop gain (sensitivity) at 100 Hz: 

10 mV/Pa - 40 dBV in re.  to 1V/Pa 

Electrical impedance: 

d

200 Ohm 

Recommended load impedance: 

t

 1000 Ohm 

Equivalent sound pressure level acc. to  
IEC 60268-4 (A-weighted): 

17 dB-A 

S/N ratio in re. to 1 Pa (A-weighted): 

77 dB 

Sound pressure limit: 

80 Pa (132 dB) for 1000 Hz 

Operating conditions: 

- Temperature:  
-20°C to +60°C 
- Relative humidity:  
99% (+20°C), 95% (+60°C)

 

Supply voltage: 

9 to 52 V phantom power acc. to IEC 61938  

Current consumption: 

d

 2 mA 

Connector: 

Type XLR-3 acc. to IEC 

External dimensions: 

19 mm ø x 147 mm 

Weight: 

approx. 115 g, net 

Housing material: 

Brass 

Housing surface: 

Mat grey 

This product conforms to the standards listed in the Declaration of Conformity. To order a free copy of 
the Declaration of Conformity, visit http://www.akg.com or contact [email protected]

 

 

 

20   

C 391 B / SE 300 B 

 

Summary of Contents for C 391 B

Page 1: ...nual before using the equipement MODE D EMPLOI 22 Veuillez lire cette notice avant d utiliser le syst me ISTRUZIONI PER L USO 32 Prima di utilizzare l apparecchio leggere il manuale MODO DE EMPLEO 42...

Page 2: ...15 Summary 16 3 Application 17 Introduction 17 CK 91 Cardioid microphone capsule 17 CK 92 Omnidirectional microphone capsule 17 CK 93 Hypercardioid microphone capsule 18 CK 94 Figure eight microphone...

Page 3: ...ety regulations in force in your country and is fitted with a ground lead ATTENTION 1 Remove the housing electronics and cables before scrapping the equipment and dispose of all components in accordan...

Page 4: ...supply x CK 91 microphone capsule with frequency independent cardioid polar pattern x W 90 foam wind guard x SA 60 universal tripod connector x Robust design Special features x Minimal self noise x L...

Page 5: ...ne axis B 18 Battery power supply for one microphone H 30 Elastic suspension with very effective insulation ST 45 Small table tripod ST 46 Small table tripod for the fitted capsules ST 305 Large table...

Page 6: ...s conservative and reliable design The switchable 10 dB attenuation of the output signal is a major benefit at high sound pressure levels i e high powered sound sources and when the input stages of am...

Page 7: ...y with a short twist to the left Our modules and system accessories are designed for use in a whole range of user specific applications A brief selection of these are listed below CK 91 Cardioid micro...

Page 8: ...d or omnidirectional polar pattern CK 94 Figure eight microphone capsule CK 97C Miniature cardioid microphone capsule This miniature microphone can be used in any situation where the microphone must b...

Page 9: ...Use a soft cloth moistened with water to clean the surface of the microphone body Microphone x Wash the foam windscreen in soap suds Do not use the windscreen before it has dried completely Windscree...

Page 10: ...IEC 60268 4 A weighted 17 dB A S N ratio in re to 1 Pa A weighted 77 dB Sound pressure limit 80 Pa 132 dB for 1000 Hz Operating conditions Temperature 20 C to 60 C Relative humidity 99 20 C 95 60 C S...

Page 11: ...Specifications Frequency Response Curve Polar Pattern C 391 B SE 300 B 21...

Page 12: ...Microphones Wireless Headphones Headsets Electroacoustical Components Microphones Casques HiFi Microphones sans fil Casques sans fil Micros casques Composants acoustiques Microfoni Cuffie HiFi Microf...

Reviews: