background image

941211-000 -D1

OPERATING MANUAL

SESAM 800

L15, M6, S6, S3, K3, RXD, RX, RX DIN

Summary of Contents for SESAM 800 K3

Page 1: ...941211 000 D1 OPERATING MANUAL SESAM 800 L15 M6 S6 S3 K3 RXD RX RX DIN...

Page 2: ...___________________ 14 7 1 Sesam 800 RX ____________________________________________14 7 2 Sesam 800 RXD Model______________________________________15 7 3 Sesam 800 RX DIN_____________________________...

Page 3: ...to a Memory Card___________________ 27 9 Description of the Transmitters_________________________ 28 9 1 Indicators on the Transmitter__________________________________28 10 Replacing Batteries in the...

Page 4: ...way the set of outputs is used for controlling the doors depends on the specific installation and is outside the scope of the Sesam The complete remote control system where the controlled object is o...

Page 5: ...fications RX RXD IP class IP65 Power Supply 12 24 V DC versions 12 24 V AC DC 150 mA SELV max 4A fuse Power Supply 230 V AC versions 230 V AC 50 Hz 15 mA max 4A fuse Max switching capacity of relays 2...

Page 6: ...type 2 AAA LR03 Alkaline Screw Size PH00 Specifications S6 IP class IP67 Dimensions 75 x 46 x 22 mm Weight 80g Battery type 2 AAA LR03 Alkaline Screw Size PH00 Specifications M6 IP class IP67 Dimensio...

Page 7: ...N only as 12 24 V AC DC Sesam 800 RX 3 Single Pole Double Throw relays Memory capacity up to 100 transmitters Sesam 800 RXD 3 Single Pole Double Throw relays Integrated display and configuration butto...

Page 8: ...ical func tions Small S3 Small size 3 button transmitter Suitable for controlling 3 func tions Small S6 Small size 6 button transmitter Suitable for controlling 6 func tions Medium M6 Medium size 6 bu...

Page 9: ...per J1 High Security Transmission Mode setting 10 Learn Erase button 11 Connection to relay 1 12 Connection to relay 2 13 Connection to relay 3 14 Antenna connector 1 2 3 4 5 6 7 8 9 R1 R2 R3 4 5 6 7...

Page 10: ...esam 800 RXD 12 24 V DC AC model connections 1 Power connection 2 Connection to relay 1 3 Connection to relay 2 4 Connection to relay 3 5 Antenna connector 1 2 3 4 5 Figure 4 Sesam 800 RXD 230 V AC mo...

Page 11: ...model display and buttons 1 Learn Erase button 2 Enter button 3 Memory position up button 4 Memory position down button 5 Display Figure 6 Sesam 800 RX DIN model connections and buttons 1 Learn Erase...

Page 12: ...ardous voltage in the receiver therefore only certi fied electricians are allowed to open the lid 6 1 Placement of the Receiver Select a location that is within the environmental limitations of the re...

Page 13: ...a cable is needed contact kerstr ms Bj rbo AB 6 3 Connections on the Receiver All Models The receiver is equipped with connections for relays power and an external antenna see fig 1 fig 2 fig 3 fig 4...

Page 14: ...e as follows LED 1 Relay 1 status LED ON indicates that the relay is active LED 2 Relay 2 status LED ON indicates that the relay is active LED 3 Relay 3 status LED ON indicates that the relay is activ...

Page 15: ...decimal points Relay 2 activated Right decimal point Relay 3 activated At start up the display will show system information in the following order System version r if a memory card is installed Number...

Page 16: ...the transmit ter if buttons 1 3 shall be used for activating the relays in the receiver b Transmitter Small S6 and Medium M6 Press button 1 on the transmitter if button 1 3 shall be used for activat...

Page 17: ...flash twice c Press the Learn Erase button three times in order to activate relay three the status LED will flash three times 3 Press the button that shall be used for activating the selected relay in...

Page 18: ...relays in the receiver Press button 4 on the transmitter if button 4 6 shall be used for activat ing the relays in the receiver c Transmitter Large L15 Press the button on the transmitter that shall b...

Page 19: ...utton 1 3 shall be used for activat ing the relays in the receiver Press button 4 on the transmitter if button 4 6 shall be used for activating the relays in the receiver c Transmitter Large L15 Press...

Page 20: ...selected memory position 4 The display will show D E L and return to normal operation Erasing all transmitters 1 Press the Learn Erase button The display shows L r n followed by the memory position th...

Page 21: ...st digit of the code by using the and buttons Press the Enter button when finished Repeat the above step for digit 2 4 When all 4 digits are entered the display will show rpt repeat The code must be r...

Page 22: ...nds The display will show LOC when the receiver switches to locked mode To change delete Receiver PIN do the following The PIN can only be changed by unlocking the receiver and making a delete all era...

Page 23: ...relays in the receiver Press button 4 on the transmitter if button 4 6 shall be used for activat ing the relays in the receiver c Transmitter Large L15 Press the button on the transmitter that shall...

Page 24: ...lay in the receiver If the configuration is accepted by the receiver LED 7 flashes 3 times 4 Mount the lid on the receiver see basic configuration 8 3 3 Erasing All Transmitters in the Receiver SESAM...

Page 25: ...em ory This mode makes it difficult to scan and record messages that could with the right technology open doors without using an authentic coded transmitter 1 2 3 4 5 6 7 8 9 R1 R2 R3 Normal mode Secu...

Page 26: ...py operation on a new receiver 8 5 1 Copying Information from a Memory Card to a New Receiver 1 Power off the receiver 2 Unscrew the 6 screws holding the receiver lid 3 Carefully remove the display ca...

Page 27: ...ove the lid 3 Carefully remove the display card 4 Insert the memory card that you want to copy all parameters to in the memory card slot see fig 10 5 Mount the display card in the display card slot se...

Page 28: ...ndications 3 long RED flashes Battery depleted transmitter can not send commands Continuous RED after activating command Low battery Very quick flashing RED Hardware error After battery insertion Yell...

Page 29: ...gure 13 The Sesam 800 S6 transmitter indicators and buttons 1 Status LED 2 Buttons 1 6 The Sesam 800 M6 6 button transmitter 1 2 Figure 14 The Sesam 800 M6 transmitter indicators and buttons 1 Status...

Page 30: ...e that changing of batteries must take place in a clean environment free from static electricity The batteries are changed as follows 1 Open the battery cover by unscrewing the 3 screws on the backsid...

Page 31: ...replace the batteries promptly Before changing the batteries note that changing of batteries must take place in a clean environment free from static electricity The batteries are changed as follows 1...

Page 32: ...teries promptly Before changing the batteries note that changing of batteries must take place in a clean environment free from static electricity The batteries are changed as follows 1 Open the batter...

Page 33: ...batteries are changed as follows 1 Open the battery cover by unscrewing the 6 screws on the backside of the transmitter housing see fig 25 2 Carefully remove the cover by lifting up the front of the c...

Page 34: ...abell 2 Error codes Sesam 800 RXD Id already programmed 1 Memory full 2 Memory card mismatch during power up 10 Memory card write error Possible memory card removal during operation 11 Memory card cop...

Page 35: ...1211 000 Version D1 Author SH 12 Receiver Drill Measure for RX and RXD 102 103 5 mm 102 mm 120 mm 145 mm 120 mm 225 mm Figure 28 The receiver shall be attached with 4 mm screws that are suitable for t...

Page 36: ...str ms Bj rbo AB Box 7 SE 785 21 Gagnef Sweden street Bj rbov gen 143 SE 785 45 Bj rbo Sweden Phone 46 241 250 00 Fax 46 241 232 99 E mail sales akerstroms com www akerstroms com kerstr ms Bj rbo AB 2...

Reviews: