background image

P A R A P I O N ™

STANDING   FRAME

USER MANUAL

Summary of Contents for PARAPION

Page 1: ...P A R A P I O N STANDING FRAME USER MANUAL ...

Page 2: ...trading changes in the content of the instruction without warning Product marked with the CE sign is Class I medical device of rule 1 consistent with the requirements of Regulation EU 2017 745 of the European Parliament and of the Council of 5 April 2017 on medical devices Akces Med Sp z o o Company introduced quality management system ISO 13485 regarding production sales and service The system is...

Page 3: ...or use 5 3 General characteristics of standing frame 7 4 Size table 9 5 Mounting the standing frame 10 6 Rules of adjusting the standing frame to the user 11 7 The use of standing frame 15 8 Safety rules 19 10 Maintenance and cleaning 22 11 Labelling 25 9 Terms of warranty 21 ...

Page 4: ...he standing frame is equipped with four noiseless castors which enable easy relocation of the user If you have any questions or remarks do not hesitate to contact with us We know very well how important it is for the user to adopt the standing position that is why we have created a product called PARAPION which is ideally suited for this purpose PARAPION allows you for full and safe upright standi...

Page 5: ... spinal cord injuries with lower limbs paralysis and weakness cerebral palsy various types and forms balance and motor coordination disorders with different etiology muscles diseases with weakness and paralysis dystrophy myasthenia gravis myositis genetic disorders egeneration and neurological diseases paresis other condition connected with muscles weakness paralysis and after head and spinal cord...

Page 6: ...ase of people with impaired cardiovascular system arterial hypertension at rest above 200 110 mmHg pulmonary hypertension cardiac arrythmias moderate heart valve disease respiratory system unstable asthma and unstable metabolic disorders it is necessary to monitor the user while standing in order to prevent serious complications People with significant flexion in the hip or knee joints as well as ...

Page 7: ...ce with chest belt adjustable 7 Tray with plate size 1 3 Adjustable knee support 5 Pelvic brace with pelvic belt adjustable 6 Low armpit supports GENERAL CHARACTERISTICS OF STANDING FRAME 3 1 Standard equipment 1 7 3 5 4 2 7 www akces med com 48 17 864 04 70 produkcja akces med com ...

Page 8: ..._140 Chest support PPN_157 Pelvic support PPN_158 Longer chest belt PPN_159 PPN_401 Independently adjustable knee supports Forearm supports Longer pelvic belt Tray High armpit supports Tango Wheel 75 100 125 mm Soft cover for tray Belt for moving patients AM P 8 www akces med com 48 17 864 04 70 produkcja akces med com ...

Page 9: ...12 22 16 24 20 31 H Knee supports height cm 18 45 24 49 31 71 I Footer length cm 23 27 30 5 Max user weight kg 30 55 95 Note Measurement tolerance range is 1 cm in This measurement cannot be the main parameter while choosing the product size Weight and dimensions Unit Size 1 Size 2 Size 3 Width cm 56 56 67 Lenght cm 75 87 93 Height cm 73 92 107 Weight kg 17 21 5 27 5 Note Measurement tolerance ran...

Page 10: ... hip support into the guides placed in the frame as seen in the figure Next we mount the chest support in a similar way Afterwards we mount the table and foot stabilizator in any order as shown in the picture Pelvic support Chest support Tray Knee support 10 www akces med com 48 17 864 04 70 produkcja akces med com ...

Page 11: ...er of the thighbone At this height set the pelvis hip support 3 Measure the distance between the ground and axillary armpit Set the chest support at this height RULES OF ADJUSTING THE STANDING FRAME TO THE USER 6 WARNING Adjustment of the standing frame to the patient is done by trained personnel only All exercises must be performed only in the company of appropriately trained personnel 11 www akc...

Page 12: ...to the metal clamp support and fastening the straps 6 Stabilize the knees in previously set knee supports by additionally fastening the stabilization straps In the case of occurrence of abduction adduction in the forefoot of the patient the feet in the foot stabilizer should be set at an appropriate angle 7 Open the hip and chest supports 12 www akces med com 48 17 864 04 70 produkcja akces med co...

Page 13: ...ort fastening Pelvic support fastening 8 We position the patient in standing frame 9 Fasten the hip and chest supports additionally securing with belts 13 www akces med com 48 17 864 04 70 produkcja akces med com ...

Page 14: ...nees coincide in a straight line If not than we should adjust the hip knees and chest support so that the patient stands straight This is very important as it prevents the formation of contractures in the ankle joints knees and hips 14 www akces med com 48 17 864 04 70 produkcja akces med com ...

Page 15: ... be secured to function properly and not to disturb during using the product Before using the product it is essential to make sure that 9 1 Preparation of the patient 7 CAUTION PARAPION has to be used with compliance to guidelines included in this user manual Remember to use the product only with someone who is trained and knowledgeable Do not forget to prepare both product as well as patient befo...

Page 16: ...s Unfold the device Equipment works correctly only when the device is adjusted according to patient s height as well as weight Remember to take all these measurements into account while purchasing the product Correct adjustment is the most important due to the fact that only then the product is safe It is forbidden to force child to keep specific position because he she will feel uncomfortable and...

Page 17: ...frame to the patient As far as first upright standing is concerned it takes place in rehabilitation neurosurgery or orthopedics wards Moreover it has to be performed together with doctor and physiotherapist due to the fact that medical problems may appear during first treatments such as fainting drop in blood pressure dizziness etc Upright standing is continued in home together with trained staff ...

Page 18: ...d person or therapist If any of these side effects appear it is highly important to stop the upright position process take out the patient from the device and lie him her down If these undesirable side effects still occur it is necessary to contact doctor If these side effects disappeared remember to inform doctor so as to make decision concerning further upright position process 18 www akces med ...

Page 19: ...alling out make sure that all movable parts and knobs for adjustments are stable and locked adjust the device according to patient s measurements and needs check if all screws knobs and all glued sewed or tapped parts are tightened check if brakes are operating correctly It is highly important to consult either doctor or physiotherapist in order to make right decision concerning the choice of PARA...

Page 20: ...t is placed in the device or not 8 It is important to engage brake during getting into and getting out the device 4 It is forbidden to leave the patient unattended 12 Before using the stander remove all paper and plastic packaging The packaging is not a toy Keep away from children and animals This device can be only used inside the buildings The device contains small parts which children may swall...

Page 21: ...1 Akces MED Sp z o o sells products free from manufacturing defects or faults 5 If product is damaged please contact our dealer or Akces MED Sp z o o customer service ph 17 864 04 77 The weight of user should not be bigger than maximal weight described on page 9 where you will find information regarding this issue It is forbidden to make any changes concerning device s structure due to the fact th...

Page 22: ...me which is a medical device should always be kept clean PARAPION and should be used in accordance with the manufacturer s instructions The standing frame should be kept in a clean dry and ventilated room Maintenance and cleaning must be done at least once a month Periodic cleaning and maintenance of the device is essential to keep its proper functioning and safety 3 Remember to remove excess mois...

Page 23: ...king and all screws nuts knobs etc are correctly tightened Manufacturer takes responsibility only for hidden faults or damages which appeared despite the fact that user complied with the guidelines In case of any damages it is essential to contact the person who sold you the product The manufacturer of the standing frame Akces MED Sp z o o is not responsible for any damages caused by using unsuita...

Page 24: ...ly mounted if applicable ź if the elements securing the user are properly mounted and if they work well if applicable Check all the mechanisms of the product and its moving parts Check in particular ź if all the moving parts are complete work properly do not jam In case of any damage or defects discontinue the use of the product and contact your Supplier Distributor or the Manufacturer Upholstery ...

Page 25: ...tributor or the Manufacturer Once a month Once every 6 months Construction moving parts In case of any damage or defects discontinue the use of the product and contact your Supplier Distributor or the Manufacturer Check ź tire wear condition Check for visible damage Check tire pressure if applicable Product labeling ź if the moving parts of the construction have not been damaged Maintain them usin...

Page 26: ...n date Store in a dry place The product does not contain latex Prohibition to leave the patient without care during use of the product Prohibition of use without fastened safety belts Declaration that the product meets the essential requirements SN REF CL Protect from sunlight Do not chlorinate Do not iron Do not bleach Do not dry in a drum dryer Careful Delicate content Dry vertically Relative hu...

Page 27: ......

Page 28: ...ised Dealer Date of issue 15 09 2006 The last update 20 05 2021 SławomirWroński 2021 MANUFACTURER Jasionka 955B 36 002 Jasionka tel 48 17 864 04 70 e mail export akces med com Akces MED Sp z o o BDO 000031619 ...