![AKA SOREX PRO Operating Manual Download Page 30](http://html.mh-extra.com/html/aka/sorex-pro/sorex-pro_operating-manual_2883609030.webp)
Selective Metal Detector SOREX PRO. Operating manual.
AKA LLC +7(495)623-4026 621-0481 http://aka.2000.ru [email protected]
30
Hold the button
in the operating mode to see settings The status of
settings is displayed on the screen depending on two search programs you have selected.
Exit settings quick review pressing
or automatic exit in 7 seconds.
Evaluation of the target size
When using the main algorithm MSF the "column" of the signal duration is shown in the
left part of the screen. It renders information on the size of the zone in which the device
interacts with the objects. The height of this "column" may depend either on the size of
the object or the sweep speed. Thus, if you train to make sweeps with steady cycles
(tempo), the size of targets may be evaluated. Taking into account that the each sweep
has its own speed it is very important to evaluate target size only when it is in the middle
of the sweep, provided that the target is located under the center of the searchcoil. This
option is not active in the M/T mode. It can be explained by specifics of the operation of
this algorithm. In trashy areas the evaluation may be incorrect due to several targets in
the searchcoil response zone.
Troubleshooting
In case of any malfunctions, first of all, reset your device to factory settings.
Turn off the device, press "M" button on the panel and turn on the device, holding it till
the startup screen appears. You will see a "Factory Settings" onscreen message. In most
cases this reset will solve the problem.
Phantom search signals when there is no metal targets are possible in following cases:
1.
Incorrect ground balancing. With incorrect ground balancing, when the balance
phase (a digit in the left corner of the screen) is shifted to the "minus" values too
much, false responses are possible in the nonferrous metals sector when
bumping the searchcoil over mounds and plants. Balance the device accurately
or adjust ground phase value by 1-2 degrees in the manual balancing mode
pressing "+". If the balancing phase is shifted to the "plus" values too much, false
responses are possible in the iron sector. Balance the device accurately or
adjust ground phase value by 1-2 degrees in the manual balancing mode
pressing "-".
2.
Weakened contact in the slot of the coil jack in the module. Put the device into
horizontal position and tap the unit cable with your finger. If the device
responds with sound signals, the problem is in the slot. Slightly force apart pin
sections of the unit (approximately 1 mm) and screw the nut tightly. If it did not
help, your device is likely to have a defective searchcoil jack soldering, or the
jack is damaged and repair is necessary.
3.
If a light finger tapping on a coil (see section "Searchcoil Replacement")
connected to a balanced device such device gives short tone signals, then the
searchcoil is defective and subject to repair or replacement. The 15 DD
searchcoil may give light phantom responses when bumping over the edges of
the coil circle, it is a design feature of the large searchcoil.