Socket (type F) switches on/off the 230 V~ power supply, opening one pole by
the user command in the 

 or automatically according t

,

.

Socket (type F) is protected against voltage overload (exceeding the range of
184–253 V~) or overcurrent (exceeding 11 A). In case of overload, the power
supply switches off, resuming automatically when voltage restored to   normal
values. In case of overcurrent, the power supply switches off automatically, but
can only be restored manually by the user command in the Ajax app.

The maximum resistive load is 2.5 kW. When using inductive or capacitive loads, the
maximum switching current is reduced to 8 A at 230 V~.

Socket (type F) with  rmware version 5.54.1.0 and higher can operate in pulse or
bistable mode. With this  rmware version you can also select the relay contact
status:

Socket (type F) with  rmware version below 5.54.1.0 only works in bistability
mode with a normally open contact.

In the app, users can check the power or amount of energy consumed by
electrical appliances connected via Socket (type F).

At low loads (up to 25 W), current and power consumption indications may be displayed
incorrectly due to hardware limitations.

Ajax app

a scenario

Button press a schedule

Normally closed

 — Socket (type F) stops supplying power when activated,

and resumes when turned off.

Normally open

 — Socket (type F) supplies power when activated, and stops

feeding when turned off.

How to  nd out the  rmware version of the device?

Summary of Contents for Socket Type F

Page 1: ...d Connecting to the Ajax security system via a secured radio protocol the device supports communication at a distance of up to 1 000 m in line of sight Socket type F operates with only and does not su...

Page 2: ...o Socket models are available with a type G and a type F Functional Elements Operating Principle UK plug European plug Buy smart plug Socket type F 1 Two pin socket 2 LED border 3 QR Code 4 Two pin pl...

Page 3: ...8 A at 230 V Socket type F with firmware version 5 54 1 0 and higher can operate in pulse or bistable mode With this firmware version you can also select the relay contact status Socket type F with fi...

Page 4: ...he app and create at least one room Ajax app 3 Make sure that the hub is not armed and it does not update by checking its status in the Ajax app 1 Click Add device in the Ajax app 2 Name the device sc...

Page 5: ...same object when unpaired correctly the Socket type F LED frame continuously blinks green If the device has not been correctly unpaired do the following to connect it to the new hub Socket type F can...

Page 6: ...t type G states are available in the Ajax app To access them Parameter Value Jeweller Signal Strength Jeweller is a protocol for the transmission of events and alarms The field displays the Jeweller s...

Page 7: ...of value updates depends on the Jeweller settings The default value is 36 seconds Values of current are displayed in increments of 10 mA Current Protection Indicates whether the overcurrent protection...

Page 8: ...Jeweller settings The default value is 36 seconds The counter is reset when the Socket type F lose the power Temporary Deactivation Shows the state of the device temporary deactivation function Firmw...

Page 9: ...e Settings are available with firmware version 5 54 1 0 and higher Contact status Selection of the normal state of the plug contacts 1 Go to the Devices tab 2 Select Socket type F in the list 3 Go to...

Page 10: ...narios Opens the menu for creating and configuring automation scenarios Scenarios offer a brand new level of property protection With them the security system not only notifies about a threat but also...

Page 11: ...s the device from the hub and deletes its settings Indication Socket type F informs the user of the power level consumed by connected appliances using the LED If the load is more than 3 kW purple the...

Page 12: ...ot begin immediately but not later than over a single hub smart plug polling period 36 seconds with the Jeweller standard settings You can change the ping period of devices in the Jeweller menu of the...

Page 13: ...e extender 1 Outdoors Doing so may cause the device to malfunction or not work correctly 2 Near metal objects or mirrors e g in a metal cabinet They can shield and attenuate the radio signal 3 Inside...

Page 14: ...t Electromagnetic relay Service life At least 200 000 switches Voltage and type of external power supply 110 230 V 50 60 Hz Voltage protection for 230 V mains Yes 184 253 V Maximum load current 11 A c...

Page 15: ...905 0 926 5 MHz 915 85 926 5 MHz 921 0 922 0 MHz Depends on the region of sale Compatibility Operates with all Ajax and Maximum radio signal power 8 97 mW limit 25 mW Radio signal modulation GFSK Rad...

Page 16: ...years after the purchase If the device does not work correctly you should first contact the support service in half of the cases technical issues can be solved remotely Customer support Compliance wi...

Page 17: ...Subscribe to the newsletter about safe life No spam Subscribe Email...

Reviews: