Socket (type F) switches on/off the 230 V~ power supply, opening one pole by
the user command in the
or automatically according to
.
Socket (type F) is protected against voltage overload (exceeding the range of
184–253 V~) or overcurrent (exceeding 11 A). In case of overload, the power
supply switches off, resuming automatically when voltage restored to normal
values. In case of overcurrent, the power supply switches off automatically, but
can only be restored manually by the user command in the Ajax app.
The maximum resistive load is 2.5 kW. When using inductive or capacitive loads, the
maximum switching current is reduced to 8 A at 230 V~.
Socket (type F) with rmware version 5.54.1.0 and higher can operate in pulse or
bistable mode. With this rmware version you can also select the relay contact
status:
Socket (type F) with rmware version below 5.54.1.0 only works in bistability
mode with a normally open contact.
In the app, users can check the power or amount of energy consumed by
electrical appliances connected via Socket (type F).
At low loads (up to 25 W), current and power consumption indications may be displayed
incorrectly due to hardware limitations.
Normally closed
— Socket (type F) stops supplying power when activated,
and resumes when turned off.
Normally open
— Socket (type F) supplies power when activated, and stops
feeding when turned off.