when using night mode
Delays in Night mode
Delay turned on when using night mode
Pulse time
Pulse time of a detector or device for detecting an
alarm:
An alarm is raised if the pulse from the detector is
longer than the specified value in this setting. It
can be used as a bounce filter
Resistance
The resistance of the resistor connected to the
detector. Can be set from 1 kΩ to 7.5 kΩ in
increments of 100 ohms.
MultiTransmitter automatically measures the
resistance of the connected resistor and displays
it in this field as the recommended value
Alarm type
Selecting the detector alarm type:
The text of SMS and notifications in the event
feed depends on the selected type of alarm
Alert with a siren if alarm is detected
When enabled,
connected to the security
system signal about the alarm of the detector or
device
Temporary Deactivation
Allows the user to disconnect the device without
20 ms
100 ms
1 s
Intrusion
Fire
Medical help
Panic button
Gas