background image

surface and fall, which may lead to failure. Please note that if the device is attached
with adhesive tape, the tamper will not trigger when trying to detach it.

2. Conduct the volume level test. If KeyPad Combi is hardly audible, relocate the

device or change the volume level in the device settings.

3. Make sure it is convenient to enter passwords or use Tag/Pass. Relocate

KeyPad Combi if it is inconvenient to manage the security at the selected
location.

4. Remove the device from the SmartBracket mounting plate.

5. Attach the SmartBracket mounting plate to the surface using the bundled

screws. When attaching, use at least two fixing points. Be sure to fix the
perforated corner on the SmartBracket plate so that the tamper responds to a
detachment attempt. 

6. Slide KeyPad Combi onto the mounting plate and tighten the mounting screw

at the bottom of the body. The screw is needed for more reliable fastening and
protection of KeyPad Combi from quick dismantling.

7. As soon as the device is fixed on SmartBracket, it shall blink once with

LED 

X

 (Malfunction) — this is a signal that the tamper has been triggered. If the

LED does not blink after installation on SmartBracket, check the tamper status
in the Ajax app and make sure the plate is firmly attached.

Summary of Contents for KeyPad Combi

Page 1: ...rds and key fobs Is equipped with in built siren The device is designed for indoor installation KeyPad Combi is only compatible with running OS Malevich 2 11 and later and range extender Connection to...

Page 2: ...1 Armed indicator 2 Disarmed indicator 3 indicator Night mode 4 Malfunction indicator 5 Pass tag reader 6 Siren...

Page 3: ...utton 11 Disarm button 12 button Night mode 13 SmartBracket mounting plate to remove the plate slide it down Do not tear off the perforated part of the mount It is required for actuating the tamper in...

Page 4: ...sword or using Tag Pass you should activate wake up KeyPad Combi by sliding your hand over the touch panel from top to bottom Once you activate the device the security status indication turns on and t...

Page 5: ...s tags reader backlight Using the siren KeyPad Combi includes a fully functional Ajax security system siren The device has 2 tasks 1 Informing about alarms The device responds to triggering of the tam...

Page 6: ...out the incident Two stage arming Off the button is disabled and nothing happens after it is pressed Alarm after the Function button is pressed the system sends an alarm to the security company monito...

Page 7: ...be found in Connection KeyPad Combi is incompatible with Hub third party security central units and ocBridge Plus and uartBridge integration modules Before starting connection Only a user or PRO with...

Page 8: ...yPad Combi states You can see them in the Devices tab in the Ajax app Icon Value Jeweller signal strength Displays the signal strength between the hub or 1 Open the Ajax app If your account has access...

Page 9: ...led in KeyPad Combi settings States The states include information about the device and its operating parameters The states of KeyPad Combi can be found in the Ajax app Parameter Value Malfunction Pre...

Page 10: ...apps and the security company will receive appropriate noti cations After sending a low battery noti cation KeyPad Combi can work for up to 2 months Lid The status of the device tamper which reacts to...

Page 11: ...short beep Beep on entry exit delay When enabled the KeyPad Combi siren beeps to signal about a delay when entering leaving Notify about the entry exit delay in the Night mode If this option is enable...

Page 12: ...mbi is con gured in the Ajax app To apply the settings after the change click the Back button Parameter Value Very loud No the device operates normally and transmits all events Lid only the hub admini...

Page 13: ...e You can select all groups or just one The eld is displayed when the is enabled Access Settings Selecting the method of arming disarming Keypad code Selection of a common password for security contro...

Page 14: ...p Auto lock Time min Selecting the device keypad lock period after wrong password attempts Buttons Volume Selecting KeyPad Combi buttons volume level when pressed Alarms in group mode Selecting the gr...

Page 15: ...n settings A detailed description of the settings is Pass Tag reading When this option is active you can manage security modes using Pass Tag devices Easy armed mode change When this option is active...

Page 16: ...he Alarm option is selected for the Function button When the option is enabled the sirens connected to the security system give an alert when the button Function button is pressed Pass Tag Reset Allow...

Page 17: ...the built in siren beeps to signal about an entry delay Delay When Leaving If this option is enabled the built in siren beeps to signal about an exit delay Delay when entering for the Night mode If th...

Page 18: ...re set in the corresponding detector settings not in the keypad settings Keep in mind that KeyPad Combi does not support This function is supported by and Setting up the processing of detector alarms...

Page 19: ...isabled by default Note that the tamper reacts to the opening and closing of the lid even if the system is not armed For the KeyPad Combi siren to respond to tamper triggering in Ajax app Setting the...

Page 20: ...ne has entered the building Noti cations are con gured in two stages setting up sirens and setting up opening detectors KeyPad Combi siren settings 1 Go to the Devices menu 2 Select a hub at the top o...

Page 21: ...to save the settings 1 Go to the Devices menu 2 Select the detector 3 Go to its settings by clicking the gear icon in the upper right corner 4 Go to the Chime Settings menu 5 Select the events to be...

Page 22: ...work with and third party devices that support DESFire technology The maximum number of connected Passes and Tags depends on the hub model The connected Passes and Tags do not affect the total limit o...

Page 23: ...rsonal password is used the name of the user who armed or disarmed the system is displayed in the hub event feed and in the noti cations list If a common password is used the name of the user who chan...

Page 24: ...pany A user or PRO with administrator rights can unlock KeyPad Combi in the Ajax app Security management of the facility using a common password For example 1234 Group security management with a commo...

Page 25: ...ng a common password In this case Night mode can only be managed using a personal password if the user has the appropriate rights Security management of the facility using a personal password For exam...

Page 26: ...ation The Ajax app and sirens installed at the facility will not give the user away in this case but the security company and other users will be warned about the incident Both personal and common dur...

Page 27: ...ate the device keypad by swiping your hand over it 2 Enter the common duress code 3 Press the disarming button 1 Activate the device keypad by swiping your hand over it 2 Enter the User ID 3 Press the...

Page 28: ...settings With the update users can mute re alarms in their groups without affecting detectors in the groups to which they do not have access Indication KeyPad Combi indicates alarms delays when enter...

Page 29: ...Event Indication Alarm KeyPad Combi siren beeps The duration and volume of the alarm depends on the settings Delay when entering leaving KeyPad Combi siren beeps about once a second The volume depend...

Page 30: ...uthorised card or key fob usage Long beep during which all keypad LEDs blink 3 times The batteries are low After changing the security mode LED X Malfunction lights up The touch buttons are locked for...

Page 31: ...cannot guarantee that the touch buttons will work properly It is a good practice to install KeyPad Combi 1 3 to 1 5 meters above the oor for convenience Install the device on a at vertical surface Thi...

Page 32: ...n of KeyPad Combi use the Convenience of use and audibility of the siren Install KeyPad Combi so that it is convenient to use it The device should not be obstructed with various objects and access to...

Page 33: ...trical wiring This may cause communication interferences Outdoors This could damage the device In places where the audio signal can be jammed 1 Attach KeyPad Combi to the surface with double sided adh...

Page 34: ...the SmartBracket mounting plate to the surface using the bundled screws When attaching use at least two xing points Be sure to x the perforated corner on the SmartBracket plate so that the tamper resp...

Page 35: ...ensitivity of the keypad The batteries installed in KeyPad Combi provide up to 3 5 years of autonomous operation at default settings If the battery is low the system sends appropriate noti cations and...

Page 36: ...password is entered three times Protection against attempts to use card or key fob not bound to the system Yes The keypad is locked for the time de ned in the settings Frequency band 868 0 868 6 MHz o...

Page 37: ...fe 10 years Warranty 24 months Warranty The warranty for the AJAX SYSTEMS MANUFACTURING Limited Liability Company products is valid for 2 years after purchase and does not extend to the bundled batter...

Page 38: ......

Reviews: