Jeweller Signal Strength Test

mode

Detection Zone Test

Switches the detector to the detection area test

Attenuation Test

Switches the detector to the signal fade test
mode (available in detectors with 

fi

rmware

version 3.50 and later

)

Temporary Deactivation

Allows the user to disconnect the device
without removing it from the system.

Two options are available:

The system can also automatically deactivate
devices when the set number of alarms is
exceeded or when the recovery timer expires.

User Guide

Opens the detector User Guide

Unpair Device

Disconnects the detector from the hub and
deletes its settings

Event

Indication

Note

Entirely

 

— the device will not execute system

commands or participate in automation
scenarios, and the system will ignore device
alarms and other noti

fi

cations

Lid only

 

— the system will ignore only

noti

fi

cations about the triggering of the

device tamper button

Summary of Contents for DoorProtect Plus

Page 1: ...tect Plus can operate up to 5 years from a pre installed battery and capable to detect more than one million openings The user can configure the detector via the for iOS macOS Windows or Android The a...

Page 2: ...ched to the moving wing or sliding part of the door If the sealed contact reed relay is within 1 DoorProtect Plus 2 Big magnet should be placed to the right of the detector 3 Small magnet should be pl...

Page 3: ...ening use only the detector part without magnets and disable the primary detector in the settings The accelerometer detects shocks and vertical deviation relative to the initial position of more than...

Page 4: ...nection via Ethernet cable and or GSM network 3 Make sure that the hub is disarmed and does not update by checking its status in the Ajax app 1 Select Add Device in the Ajax app 2 Name the device scan...

Page 5: ...tor connected to the hub appears in the list of devices in the app The update of the detector statuses in the list depends on the device ping interval set in the hub settings the default value is 36 s...

Page 6: ...r Indicates whether the shock sensor is active Tilt Sensor Indicates whether the tilt sensor is active Temporary Deactivation Shows the status of the device temporary deactivation function No the devi...

Page 7: ...entering alarm activation delay is the time you have to disarm the security system after entering the room Delay When Leaving sec Selecting the delay time when exiting Delay when exiting alarm activat...

Page 8: ...the normal angle of the sensor Above this limit the sensor detects an alarm Tilt Alarm Delay The number of seconds from the moment the sensor is tilted to the alarm Always Active When turned on the de...

Page 9: ...s are available The system can also automatically deactivate devices when the set number of alarms is exceeded or when the recovery timer expires User Guide Opens the detector User Guide Unpair Device...

Page 10: ...ts do not start immediately but within 36 seconds by default The starting time depends on the ping interval the paragraph on Jeweller settings in hub settings The location of DoorProtect Plus depends...

Page 11: ...tector in the perpendicular planes inside the case frame use the small magnet from the set The distance between the magnet and detector should not exceed 1 cm 1 outside the premises outdoors 2 nearby...

Page 12: ...wired detector with an NC normally closed contact type can be connected to DoorProtect Plus using the in built terminal clamp We recommend installing the wired detector at a distance no longer than 1...

Page 13: ...that you have selected the optimal location that follows the guidelines of this manual 1 Fix the SmartBracket attachment panel using bundled screws If you use any other attachment tools make sure tha...

Page 14: ...its quality detector triggering frequency and ping interval by the hub If the door opens 10 times a day and the detector ping interval is 60 seconds then DoorProtect Plus operates 7 years from the pre...

Page 15: ...p to 5 years Installation method Indoors Protection class IP50 Operating temperature range From 10 to 40 Operating humidity Up to 75 Dimensions 20 90 mm Weight 29 g Service life 10 years Certification...

Page 16: ...MPANY products is valid for 2 years after the purchase and does not apply to the pre installed battery If the device does not work correctly you should first contact the support service in half of the...

Reviews: