AJA RH10MD2 Dual HD Down Converter User Manual

 

User Controls

 

The user interface for configuring the RD10MD2 and 
selecting output formats is a pair of dipswitches at 
the front of the card and several jumpers in the 
middle and at the back of the card (see J2, J3, J5, and 
J6 in the photo below). 

Two multi-color LEDs at the front of the card 
additionally show the type of input present at each 
channel (HD=Orange or SD=Green).

The loop outputs always reflect the reclocked input. 
Each channel has a reclocked looped output.

The format of the downconverter outputs, either SDI 
or analog composite, are configured by the jumpers 
J5 and J6. Jumpers J2 and J3 configure the HD to SD 
delay and the type of embedded timecode (RP188 or 
RP215). Tables later in the manual define the jumper 
settings and their corresponding meanings.

 

RD10MD2 Card Module, User Controls

LEDs

  DIP

Channel

1

  DIP

Channel

2

DIP

Switches

J2    J3

J5

J6

Summary of Contents for RD10MD2

Page 1: ...www aja com Installation and Operation Guide B e c a u s e i t m a t t e r s RD10MD2 Dual HD to SD Down Converter R series Card Module Published 6 30 10...

Page 2: ...iod and make suitable arrangements for the performance of service The Customer shall be responsible for packaging and shipping the defective product to a designated service center nominated by AJA Vid...

Page 3: ...own The SD output can be formatted for either 4 3 or 16 9 monitors For 4 3 monitors both Letterbox and Crop modes are supported The RD10MD2 is dual rate HD SD and supports SDI inputs The RD10MD2 is co...

Page 4: ...Input HD SDI Reclocked Output 1 SD Digital Out or Analog Composite Out Composite Encoder Downconvert ReClock CH 2 HD SDI Input HD SDI Reclocked Output 1 SD Digital Out or Analog Composite Out Composit...

Page 5: ...show the type of input present at each channel HD Orange or SD Green The loop outputs always reflect the reclocked input Each channel has a reclocked looped output The format of the downconverter out...

Page 6: ...tion Details 1 Pedestal UP Pedestal Off DOWN Pedestal On 2 Crop UP Crop On the Horizontal Edges are cropped off from the input lines all output lines are used DOWN Crop Off black bars are on top and b...

Page 7: ...RP188 embedded timecode Jumper placed in 2B Select Channel 1 to have RP215 embedded timecode J3 Channel 2 Jumper placed in 1A Sets Channel 2 HD to SD delay to align with VSYNC per Panasonic deck Jump...

Page 8: ...er Cord Notice please read this To reduce the risk of electrical shock disconnect both power cords before servicing equipment Caution The FR1 FR2 front fan door is heavy and is not hinged Remove with...

Page 9: ...t 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interferen...

Page 10: ...0004 6 2007 EN61000 4 11 2004 The product is also licensed for additional country specific standards as required for the International Marketplace Warning This is a Class A product In a domestic envir...

Page 11: ...manual Before operating your unit please read the instructions in this document Warning Read and follow all warning notices and instructions marked on the product or included in the documentation Aver...

Page 12: ...allare in conformit con le istruzioni del fornitore Warning Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Avert...

Page 13: ...ovesciato del liquido stato rovesciato o qualche oggetto caduto nel dispositivo il dispositivo stato esposto a pioggia o umidit non funziona correttamente o caduto Caution This device is a Class A pro...

Page 14: ...l los cable s el ctrico s del equipo La toma de corriente debe ser instalada cerca del equipo y debe estar f cilmente accesible Advert ncia Certifique se de que a alimenta o principal esteja desconect...

Page 15: ...ec pr caution Achtung Die vordere Gebl set r des FR1 FR2 ist schwer und l sst sich nicht klappen Bitte vorsichtig entfernen Precauci n La puerta del ventilador delantero del FR1 FR2 es pesada y no pos...

Page 16: ...16...

Reviews: