![Aiwa XR-MDS7 EZ Service Manual Download Page 10](http://html1.mh-extra.com/html/aiwa/xr-mds7-ez/xr-mds7-ez_service-manual_2882807010.webp)
– 10 –
• PCMD is a MSB first, two's complement output.
• GTOP is used to monitor the frame sync protection status. (High: sync protection window released.)
• XUGF is the frame sync obtained from the EFM signal, and is negative pulse. It is the signal before sync
protection.
• XPCK is the inverse of the EFM PLL clock. The PLL is designed so that the falling edge and the EFM
signal transition point coincide.
• The GFS signal goes high when the frame sync and the insertion timing match.
• RFCK is derived from the crystal accuracy, and has a cycle of 136
µ
s.
• C2PO reqresents the data error status.
• XROF is generated when the 16K RAM exceeds the
±
4F jitter margin.
Monitor Pin Output Combinations
Command bit
0
0
XUGF
XPCK
GFS
C2PO
0
1
MNT1
MNT0
MNT3
C2PO
1 0 RFCK XPCK XROF GTOP
NOTES
MTSL1
MTSL0
Output Data
Summary of Contents for XR-MDS7 EZ
Page 7: ...7 IC BLOCK DIAGRAM...