3-5.
V SIZE Vertical Size Adjustment
PAL
Adjustment Menu No. 29 (Page 3-5)
Input signal : Crosshatch
Measuring instrument : Pattern generator / PAL
•
Use the volume keys on the jig remote controller and adjust A to position the dot
mark in the center to the exact vertical centre of the crosshatch pattern on the screen
and regularize the squares of the crosshatch pattern. (Fig. 3-5)
NTSC
Adjustment Menu No. 85
Input signal : Crosshatch
Measuring instrument : Pattern generator / NTSC
•
Using the “ CHANNEL” key, scroll through the adjustment menu and select No. 85.
To adjust, follow the same procedure as PAL.
3-6.
SUB TINT Sub-Tint Adjustment
Adjustment Menu No. 30 (Page 3-6)
Input signal : Color bar (VIDEO IN)
Measuring instrument : Oscilloscope
Pattern generator / NTSC
Test point : CN901
3
PIN B
1. Connect oscilloscope to the test point.
2. Using the volume keys on the jig remote controller, adjust the top
excursions of waveform to be linear. (Fig. 3-6)
4-1.
V LINEARITY Vertical Linearity Adjustment
PAL
Adjustment Menu No. 4
Input signal : Monoscope (LION MARK)
Measuring instrument : Monoscope / PAL
•
Use the volume keys on the jig remote controller to adjust the 6 circular
figures on monoscope to be true circles. (Fig. 4)
[Simple Adjustment]
Adjustment Menu No. 4
Input signal : Crosshatch
Measuring instrument : Pattern generator / PAL
•
Use the volume keys on the jig remote controller make crosshatch patterns
square.
* Check V POS (PAGE 1-2 / PAL) and V SIZE (PAGE 3-5 / PAL) after
completting the adjustment. Re-position each dot in case it is not at the right points.
NTSC
Adjustment Menu No. 77
Input signal : Monoscope (LION MARK)
Measuring instrument : Monoscope / NTSC
•
Use the “ CHANNEL” keys to scroll through the adjustment menu and set to No. 77. To adjust, follow the same procedure as for PAL.
[Simple Adjustment]
Adjustment Menu No. 77
Input signal : Crosshatch
Measuring instrument : Pattern generator / NTSC
•
Use the “ CHANNEL” keys to scroll through the adjustment menu and set to No. 77. To adjust, follow the same procedure as for PAL.
* Check V POS (PAGE 1-2 / NTSC) and V SIZE (PAGE 3-5 / NTSC) after completing the adjustment. Re-position each dot in case it is not
at the right point.
Fig. 4