ELECTRICAL ADJUSTMENT -2/7
<TUNER SECTION>
1. VT Check (AM)
Requirements
• Measuring instrument: Digital multimeter
Test points: VT, GND
1) Connect the digital multimeter between VT and GND.
2) Set the function to AM, and tune the receiving frequency of the unit at 1,710 kHz.
3) Check that the digital multimeter ranges under 9 V.
4) Tune the receiving frequency of the unit at 530 kHz.
5) Check that the digital multimeter ranges above 0.5 V.
2. VT Adjustment and Check (FM)
Requirements: Same as the above.
• Adjustment point: L907
1) Connect the digital multimeter between VT and GND.
2) Set the function to FM, and tune the receiving frequency of the unit at 108.0MHz.
3) Adjust L907 so that the digital multimeter ranges at 9.0
±
0.1 V.
4) Tune the receiving frequency of the unit at 65 MHz.
5) Check that the digital multimeter ranges under 0.5 V.
3. CLOCK Check (AM)
Requirements
• Measuring instrument: Frequency counter
Test point: CLK(IC801 24PIN), GND
1) Connect the frequency counter between CLK and GND.
2) Set the function to AM, and tune the receiving frequency of the unit at 1,710 kHz.
3) Check that the frequency counter ranges at 2,160 kHz
±
45 Hz.