ADJUSTMENT
<TUNER SECTION>
1. AM IF Adjustment
L105 ....................................................................... 455kHz
2. AM Frequency range Adjustment
L104 ................................................ 517kHz ± 5kHz<YL>
L104 ................................515kHz ± 5kHz<EXCEPT YL>
TC104 ......................................... 1775kHz ± 10kHz<YL>
TC104 .........................1670kHz ± 10kHz<EXCEPT YL>
3. AM Tracking Adjustment
L101 ....................................................................... 600kHz
TC101 .................................................................. 1400kHz
4. FM Frequency range Adjustment
L103 ...................................... 87.4MHz ± 0.05MHz<YZ>
L103 ....................... 87.0MHz ± 0.1MHz<EXCEPT YZ>
TC103 .................. 109.0MHz ± 0.1MHz<EXCEPT YZ>
TC103 .................................108.3MHz ± 0.05MHz<YZ>
5. FM Tracking Adjustment
L102 .................................................................... 88.0MHz
TC102 ............................................................... 108.0MHz
SFR 1
A MAIN C.B
PHONES
J1
L104
L102
PVC1
TC101
TC103
TC104
TC102
BAR ANT
L105
L103
1
4
2
2
3
3
L101
VR1
6 7
6
VOLUME
5
IC1
SFR51
P HEAD
FWD
7
PVC101
(BAR-ANT)
<TAPE PLAYER SECTION>
6. Tape Speed Adjustment
Settings : Test tape :
TTA100 (Tape center)
Test point :
PHONES JACK (J1)
Volume :
NON-CLIP (MAX-10dB)
Function :
TAPE
Adjustment location : SFR51
Method : Play back the test tape and adjust SFR51 so that
the frequency becomes 3000Hz ± 10Hz(FWD).
Then confirm WOW is less than 0.50%.
7. Head Azimuth Adjustment
Settings : Test tape :
TTA330/TTA420
Test point :
PHONES JACK (J1)
Volume :
MAX
Function :
TAPE
Adjustment location : Head azimuth
adjustment screw
Method : Play back the 8kHz signal of the test tape and
adjust the screw so that the output becomes
maximum.
- 7 -