-33-
2. Jitter Check
1) While oscilloscope is kept connected in the same test point as in
4. Play Ability Check
1) Play back the 3rd , 8th and 13th track of ATD-001. Check that the noise does not occur sound skipping does not occur.
OUT PUT
ns
INPU T
TP- R F
TP- Vref
JITTER METER
OSCILLOSCOPE
OUTPUT
TP- TE
TP- Vref
OSCILLOSCOPE
ELECTRICAL ADJUSTMENT - 5/5
CD CHECK
Perform the adjustments after the main unit enters the test mode.
Place the CD mechanism on level ground.
Equipment and tools required
Measuring equipment
• Digital multi-meter
• Oscilloscope ( 10:1)
• Jitter meter (KIKUSUI 6235)
Test disc: TCD-782
ATD-001
1. Rf Waveform Check
1) Connect oscilloscope to the test point RF and Vref.
2) Play back the second track of TCD-782.
3) Check that the RF waveform has the maximum amplitude and the center
of the wedge waveform has the clear blank.
OSCILLOSCOPE
OUTPUT
TP-RF
TP-Vref