Room Air Conditioner with R-410A

Owner’s Manual 

3

Do not, under any

circumstances, cut,

remove, or bypass

the grounding prong.

Power supply cord

with 3-prong grounding plug

and current detection device

Grounding type wall

receptacle

WARNING

NOTE:

The power supply cord with this air 

conditioner contains a current detection 

device designed to reduce the risk of fire.

Please refer to the section Operation

of Current Device for details.In the event 

that the power supply cord is damaged, 

it cannot be repaired-it must be replaced 

with 

a cord from the Product Manufacturer

.  

Avoid fire hazard or electric shock. Do not

use an extension cord or an adaptor plug. 

Do not remove any prong from the power 

cord. 

WARNING

For Your Safety

WARNING

Prevent Accidents

WARNING

Electrical Information

Do not store or use gasoline or other flammable vapors and liquids in the vicinity  

of this or any other appliance.

Operation of Current Device

(Applicable to the unit

s with 

current detection 

device only )

The power supply cord contains a current device that senses 

damage to the power cord. To test your power supply cord do 

the following:

1. Plug in the Air Conditioner.

2. The power supply cord will have TWO buttons on the plug

head. Press the TEST button, you will notice a click as the

RESET button pops out.

3. Press the RESET button, again you will notice a click as

the button engages.

4. The power supply cord is now supplying electricity to the

unit. (On some products this it also indicated by a light on

the plug head.)

3

To reduce the risk of fire, electrical shock, or injury to persons when using your

air conditioner, follow basic precautions, including the following:

    Be sure the electrical service is adequate for the model you have chosen. This

    information can be found on the serial plate, which is located on the side of the

    the cabinet and behind the grille.

    If the air conditioner

 

is t o b e in stalled in  a w indow, yo u w ill pr obably w ant to  cl ean

    both sides of  the g lass f irst.I f th e w indowis a tri ple-track ty pe w ith a sc reen pa nel

    included, remove the screen completely before installation.

    Be sure the  air c onditioner

 

h as b een s ecurely a nd c orrectly in stalled a ccording to 

    the installation instructions in this manual. Save this manual for possible future

    use in removing or installing this unit.

    When handling the air  conditioner,  be  careful  to  avoid  cuts f rom s harp m

  etal f ins

    on front and rear coils. 

The complete electical rating of your new room air conditioner is stated on the 

serial plate. Refer to the rating when checking the electrical requirements.

     Be sure the air conditioner is properly grounded. To minimize shock and fire 

     hazards, proper grounding is important. The power cord is equipped with a 

     three-prong grounding plug for protection against shock hazards.

     Your air conditioner must be used in a properly grounded wall receptacle. If the 

     wall receptacle you intend to use is not adequately grounded or protected by a 

     time delay fuse or circuit breaker, have a qualified electrician install the proper 

     receptacle. Ensure the receptacle is accessible after the unit installation.

     Do not run air conditioner without side protective cover in place.This could 

     result in mechanical damage within the air conditioner.

     

Do not use an extension cord or an adapter plug.

IMPORTANT SAFETY INSTRUCTIONS

    Do not use this device to turn the unit on or off.

    Always make sure the RESET button is pushed in for 

    correct operation.

    The power supply must be replaced if it fails reset when 

    either the TEST button is pushed, or it cannot be reset. A 

    new one can be obtained from the product manufacturer.

    If power supply cord is damaged, it cannot be repaired. It 

    MUST be replaced by one obtained from the product 

    manufacturer. 

NOTE:

NOTE:

This air conditioner is designed to be operated 

            under condition as follows:

Cooling 

operation

Outdoor temp: 
Indoor temp: 

Heating 

operation

Outdoor temp: 

O

O

23-76 F/-5-24 C

Indoor temp: 

O

O

32-80 F/0-27 C

O

O

O

O

64-109 F/18-43 C (64-125 F/18-52 C 

for special tropical models)

O

O

62-90 F/17-32 C

Note: Performance may be reduced outside of these 

operating temperatures.

Summary of Contents for CD-101M

Page 1: ...81M CD 101M Heat Controller 1900 Wellworth Ave Jackson MI 49203 517 787 2100 www heatcontroller com OWNER S MANUAL Room Air Conditioner with R 410A CD 81M CD 101M AITONS 35 Brownridge Road Unit 6 Hal...

Page 2: ...Owner s Manual Room Air Conditioner with R 410A AITONS EQUIPMENT...

Page 3: ...ic shock or fire due to excess heat generation It may cause electric shock or fire due to heat generation Incorrect grounding may cause electric shock It may cause fire and electric shock It may cause...

Page 4: ...ctric shock Operation without filters may cause failure It contains contaminants and could make you sick Stop operation and close the window in storm or hurricane Do not use strong detergent such as w...

Page 5: ...des of the glass first If the windowis a triple track type with a screen panel included remove the screen completely before installation Be sure the air conditioner has been securely and correctly ins...

Page 6: ...als DO NOTuse for grounding Check with a qualified electrician if you are in doubt as to whether the appliance is pro perly grounded DO NOT modify power supply cord plug If it does not fit outlet have...

Page 7: ...sure length of your screws The scale will come in handy when separating screws for installation Identify Screws By Length 25mm 1 44mm 1 3 4 63mm 2 1 2 3 8 10mm 3 4 19mm 2 Choose a proper sized window...

Page 8: ...Owner s Manual Room Air Conditioner with R 410A AITONS EQUIPMENT 6 6 INSTALLATION INSTRUCTIONS 1 4 11 16 Window track Window seal Platform tab Alternate screw location depending on the stool depth...

Page 9: ...Room Air Conditioner with R 410A Owner s Manual 7 7 INSTALLATION INSTRUCTIONS...

Page 10: ...Owner s Manual Room Air Conditioner with R 410A AITONS EQUIPMENT 8 INSTALLATION INSTRUCTIONS 1 8...

Page 11: ...Room Air Conditioner with R 410A Owner s Manual 9 INSTALLATION INSTRUCTIONS 3 4 or 1 3 4 or 1 or 9...

Page 12: ...Owner s Manual Room Air Conditioner with R 410A AITONS EQUIPMENT 10 INSTALLATION INSTRUCTIONS 10...

Page 13: ...Room Air Conditioner with R 410A Owner s Manual 11 INSTALLATION INSTRUCTIONS 11...

Page 14: ...Owner s Manual Room Air Conditioner with R 410A AITONS EQUIPMENT 12 INSTALLATION INSTRUCTIONS 1 12...

Page 15: ...t passing through evaporator during normal operation Pinging or Swishing Droplets of water hitting condenser during normal operation may cause pinging or swishing sounds Vibration Unit may vibrate and...

Page 16: ...ing the Sleep button again TO ADJUST FAN SPEEDS SLEEP FEATURE To choose operating mode press Mode button Each time you press the button a mode is selected in a sequence that goes from Auto Cool Dry an...

Page 17: ...n will continue to run during this time The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other press and hold the Left and Right Tem...

Page 18: ...ected Push plug firmly into wall outlet House fuse blown or circuit breaker tripped Replace fuse with time delay type or reset circuit breaker Plug Current Device Tripped Press the RESET button Proble...

Page 19: ...dly Noise when unit is cooling Water dripping INSIDE when unit is cooling Improper installation Tilt air conditioner slightly to the outside to allow water drainage Refer to installation instructions...

Page 20: ...LPHQVLRQDO GDWD RQ WKH DFWXDO SURGXFW SULRU WR EHJLQQLQJ DQ LQVWDOODWLRQ SUHSDUDWLRQV QFHQWLYH DQG UHEDWH SURJUDPV KDYH SUHFLVH UHTXLUHPHQWV DV WR SURGXFW SHUIRUPDQFH DQG FHUWLILFDWLRQ OO SURGXFWV PHH...

Reviews: