28 |
P a g e
Units:
This window is used to customise the displayed
units and can be set at any time. These units will
also be used when generating the job reports.
Accessed using the
“Settings” Menu.
Calibration:
The Aitchison E-Drive Calibration provides an easier and faster means of setting up your
Seed Drill compaired to the traditional calibration process. This section describes how to set
up and complete the calibration process.
Important
: Only calibrate one hopper at a time.
Preparation
: Load the product, Prime the Hoppers and set up the product catchment.
•
Load the Product
: Load the product over the catchment outlets for calibration.
•
Prime Hoppers
: Press and hold the desired prime button until the product flows freely.
Forgetting to prime the hoppers before calibration will result in a false application rate.
•
Product Catchment
: Place catchment under the calibration outlet.
Run Calibration
:
1.
Enable Calibration Mode
: Click on the
“CALIBRATE” button in the “Settings” Menu. Enter
the Product Names for each Hopper. Then press
the “Start” button. A blank “calibrating” page will
appear.
Note:
An instructions tab can be found at the
bottom of the window.
2.
Start Calibration
: To start/pause calibration, press
the products prime button on the machine. The
calibration will stop itself automatically when complete and the interface will buzz for
1s. The interface will update, showing a weight and outlets input field for the calibrated
hopper. The second hopper can be calibrated once
the buzzer signals completion.
•
If the buzzer does not sound when the
motor stops and the interface is not
updated, quick press the prime button.
•
Only calibrate one Hopper at a time.
•
If the catchment is nearing overflow,
pause the calibration using the prime button, collect the product and continue
with an empty catchment.
•
Take note of the weight units. This can be set in the “UNITS” menu (See
3.
Collect and Weigh the Product
: Remember to “TARE” scales before weighing.
4.
Set Calibration Weight and Number of Outlets from the Hopper
: Go to the user
interface and enter the total measured weight.
Press tick [top left] button to complete the calibration process. To cancel at any time, press
the cross [top right] button. A conformation message will show up if the calibration is
successful.
1
Summary of Contents for SEEDMATIC PROFESSIONAL 8124A
Page 2: ...2 P a g e...
Page 13: ...13 P a g e SIMPLE RULES TO FOLLOW FOR SUCCESSFUL PASTURE RENOVATION...
Page 17: ...17 P a g e...
Page 20: ...20 P a g e TINE PLACEMENT 8124CTE Tine Placement...
Page 22: ...22 P a g e AITCHISON SEEDMATIC Electric Drive Head Unit...
Page 35: ...35 P a g e PARTS BREAKDOWN...
Page 36: ...36 P a g e...
Page 37: ...37 P a g e...
Page 38: ...38 P a g e...
Page 39: ...39 P a g e...
Page 40: ...40 P a g e...
Page 41: ...41 P a g e...
Page 42: ...42 P a g e...
Page 43: ...43 P a g e...
Page 45: ...45 P a g e...
Page 46: ...46 P a g e...
Page 47: ...47 P a g e...
Page 48: ...48 P a g e...
Page 49: ...49 P a g e...
Page 50: ...50 P a g e...