7
EN
System consumption
Zone settings
To create a new time schedule press and follow the instructions:
1.
Select the type of schedule and confirm:
•
Mode.
Allows you to define the operation mode (only available on master Blueface
thermostats).
•
Temperature.
Allows you to choose the temperature of the zone.
2.
Select the days of the week on which to apply the schedule and also set the time and the
action to be performed.
3.
Press the option to confirm.
To activate/deactivate or modify a schedule, press the schedule and press the On/Off selector or
the parameters you wish to modify.
When a schedule is activated, the time schedules icon will appear without being crossed out
. When it is deactivated, the icon will appear crossed out
and the schedule will be visible
in the list of schedules, but it will be disabled.
If you have Airzone Cloud with calendar schedules or weekly schedules created,
remember that these schedules have priority over those created for each zone in the
event of a conflict. The priority established for the time schedules is:
Calendar schedules or weekly schedules > zone schedules
This menu displays daily information about the consumption of your system (Airzone
consumption meter required):
•
Zone and system usage time.
•
Power consumption (instantaneous power of the AC unit and accumulated consumption
during the day).
Press on the icons to access the parameters:
Sleep mode.
Sleep mode is an eco-timer for switching off the zone. The selectable values
are:
Off.
The timer is off.
30.
Activates the timer and after 30 minutes, the zone is switched off.
60.
Activates the timer. After 30 minutes, the zone changes its temperature by one
degree and 60 minutes after activation, the zone switches off.
90.
Activates the timer. After 30 minutes, the zone changes its temperature by one
degree. 60 minutes after activation, the zone changes its temperature by another
degree. 90 minutes after activation, the zone switches off.
Anti-freezing.
Prevents the room temperature in the zone from dropping below 12°C, even
if the zone is off. (In Stop mode it will not be activated).
Depending on your installation and the configuration of your system, you can manage the
following parameters:
Grille angle.
Allows you to define an inclination on the Airzone smart grilles in the zone for
cooling and heating modes. The options are 40°, 45°, 50° and 90° (90° by default).