background image

SMB Air Conditioner 

 

12 VDC Owner’s Manual 9/09 

 

Page 5 of 13 

Chapter 3 - General Description  

 
The 12 VDC air conditioner built by Marvair® are self-contained, water-cooled units designed for use 
with either fresh or seawater. The SMB models are designed to be used with a wall mounted thermostat 
and use R-134a refrigerant.  

Operating Ranges 

The air conditioner is designed to work over a wide range of conditions. Among the most important 
factors that affect the performance of the unit are inlet water temperature, inlet (return) air temperature 
and the humidity of the inlet (return) air. Please consult your Marvair Marine dealer or the factory if you 
have a question about the operation of your air conditioner. 

 
Electrical  

The SMB model is designed to operate of a nominal 12 volt DC power supply - an inverter is not 
required. The unit will operate on a DC voltage from 9 volts to 17 volts. 

General Operation 

 

The 12 VDC air conditioner uses R-134a refrigerant in a conventional vapor compression cycle to 
transfer heat from the air in the boat to the water. In the cooling mode, a blower blows the cabin air 
through the indoor or evaporator coil where it is cooled and dehumidified. Liquid refrigerant passing 
through the evaporator is boiled into a gas by heat removed from the air. The warmed refrigerant gas 
enters the compressor where its temperature and pressure are increased. The hot refrigerant gas travels to 
the water coil or condenser where it is cooled by the water and condenses to a liquid. Liquid refrigerant is 
metered back into the evaporator coil to repeat the process. 

Summary of Contents for Marvair Marine SMB05ACP

Page 1: ...Chapter 7 Wiring Diagram 10 Chapter 8 Spare Parts List 11 Chapter 8 Warranty 12 Manufactured By Marvair Division of AIRXCEL Inc P O Box 400 Cordele Georgia 31010 156 Seedling Drive Cordele Georgia 310...

Page 2: ...point out helpful suggestions that will result in improved installation reliability or operation DANGER Self contained units or evaporators of split systems should never be installed in engine rooms...

Page 3: ...URE FAULT shutdown Supply Air Grille s Some installations will have more than one supply air grille Standard main supply air grilles are generally made of aluminum or wood frames with two or four way...

Page 4: ...me cases In such severe conditions seek the advice of your local factory service representative They will be most familiar with solutions to localized situations Marvair works closely with our servici...

Page 5: ...air conditioner Electrical The SMB model is designed to operate of a nominal 12 volt DC power supply an inverter is not required The unit will operate on a DC voltage from 9 volts to 17 volts General...

Page 6: ...dedicated breaker turn it on Verify that water is being discharged overboard Instructions for the Thermostat Cooling Cycle 1 Adjust the cooling temperature set point on the thermostat higher than the...

Page 7: ...ct water line at ball valve 3 Insert line into a bucket of potable anti freeze 4 Run air conditioner until a solid stream of anti freeze is being discharged overboard 5 Reconnect water line at ball va...

Page 8: ...ndoor coil The sensor and or thermostat should be replaced if defective 3 Check for water flow Check refrigerant charge Check switches for loose wire connection broken or burned contacts 4 Tug on wire...

Page 9: ...tional unit s if necessary 7 Add refrigerant Noise operation 1 Copper tubing is vibrating 2 Indoor blower assembly 3 Loose cabinet or components 4 Improper unit installation 1 Adjust by bending slight...

Page 10: ...SMB Air Conditioner 12 VDC Owner s Manual 9 09 Page 10 of 13 Chapter 7 Wiring Diagram...

Page 11: ...pressor 10343 Control Module 01627 Evaporator Coil 60127 Blower Assembly 30067 Control Board 50196 Condenser water coil 60194 High Pressure Switch Manual Reset 400 psig 70339 Cap Tube Strainer Assembl...

Page 12: ...heir designated Service Representative The responsibility of the Owner of the Equipment includes the following 1 To operate the equipment according to the manufacturer s instructions 2 To provide easy...

Page 13: ...HIS WARRANTY AND SERVICE POLICY CONSTITUTE THE EXCLUSIVE REMEDY OF ANY PURCHASER OF A MARVAIR REVERSE CYCLE AIR CONDITIONER AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING WITHOU...