CONTROL
SYSTEM
11-14
SM YAZ218 1-A.2 GB
Note: ‘On’ state has higher priority.
11.5.7 Thermodynamic
Protections
Protection level definition
Five protection levels are defined:
Normal – No protection status is ON.
Stop-Rise (SR) – System is in protection, first level
D1 - System is in protection, second level
D2 - System is in protection third level
Stop-Compressor (SC) – System is in protection fourth level
11.5.8
IDU Protection Level
The overall protection level of the indoor units will be the worst protection status among the
all indoor units.
11.5.9
IDU Protections
11.5.9.1
Indoor Coil Defrost Protection
ICT Trend
ICT
Fast
Increasing
Increasing
No change
Decreasing
Fast
Decreasing
ICT < -2
SC
SC
SC
SC
SC
-2
≤
ICT < 0
D1
D1
D2
D2
D2
0
≤
ICT < 2
SR
SR
D1
D2
D2
2
≤
ICT < 4
SR
SR
SR
D1
D2
4
≤
ICT < 6
Norm
Norm
SR
SR
D1
6
≤
ICT < 8
Norm
Norm
Norm
SR
SR
8
≤
ICT
Normal
11.5.9.2
Indoor Coil over Heating Protection
ICT Trend
ICT
Fast
Decreasing
Decreasing
No Change
Increasing
Fast
Increasing
ICT
>
55 SC SC SC SC SC
53 < ICT
≤
55
D1 D1 D2 D2 D2
49 < ICT
≤
53
SR SR D1 D2 D2
47 < ICT
≤
49
SR
SR
SR
D1
D2
45 < ICT
≤
47
Norm
Norm
SR
SR
D1
43 < ICT
≤
45
Norm
Norm
Norm
SR
SR
ICT
≤
43
Normal
OAT
Base Heater at heating mode
ON
OFF
-2
0
Summary of Contents for /yaz218
Page 17: ...OUTLINE DIMENSIONS SM YAZ218 1 A 2 GB 4 1 4 OUTLINE DIMENSIONS 4 1 Indoor Unit PNXA009 012 ...
Page 20: ...OUTLINE DIMENSIONS SM YAZ218 1 A 2 GB 4 4 4 5 Indoor Unit DLF09 12 DCI ...
Page 21: ...OUTLINE DIMENSION SM YAZ218 1 A 2 GB 4 5 4 6 OUTDOOR UNIT YAZ218 出气口 进气口 ...
Page 33: ...OPERATING CURVES 6 2 SM YAZ218 1 A 2 GB 6 1 2 Heating Technician Mode ...
Page 34: ...OPERATING CURVES SM YAZ218 1 A 2 GB 6 3 6 1 3 Tubing Length correction Factor ...
Page 37: ...REFRIGERATION DIAGRAM SM YAZ218 1 A 2 GB 9 1 9 REFRIGERATION DIAGRAM 9 1 YAZ218 Cooling Mode ...
Page 38: ...REFRIGERATION DIAGRAM 9 2 SM YAZ218 1 A 2 GB 9 2 YAZ218 Heating Mode ...
Page 39: ...TUBING CONNECTIONS SM YAZ218 1 A 2 GB 10 1 10 TUBING CONNECTIONS ...