5-2
PERFORMANCE DATA
SM DUO38I 1-A.2 GB
5.1.3
Heating Capacity (kW) - Run Mode(Unit A or B)
230[V] : Indoor Fan at High Speed.
ID COIL ENTERING AIR DB TEMPERATURE [C
0
]
OD COIL ENTERING AIR
DB/WB TEMPERATURE
[C
0
]
DATA
15
20
25
-15/-16
TC
1.15
1.07
1.00
PI
0.38
0.44
0.49
-10/-12
TC
1.37
1.30
1.23
PI
0.44
0.50
0.55
-7/-8
TC
1.54
1.47
0.55
PI
0.49
0.54
0.60
-1/-2
TC
1.63
1.56
1.49
PI
0.51
0.56
0.62
2/1
TC
1.68
1.61
1.54
PI
0.52
0.58
0.63
7/6
TC
2.22
2.15
2.08
PI
0.54
0.60
0.66
10/9
TC
2.31
2.24
2.17
PI
0.57
0.63
0.68
15/12
TC
2.40
2.33
2.26
PI
0.60
0.65
0.71
15-24
TC
85 - 105 % of nominal
(Protection Range)
PI
80 - 120 % of nominal
LEGEND
TC –
Total Cooling Capacity, kW
PI – Power Input, kW
WB – Wet Bulb Temp., (
o
C)
DB – Dry Bulb Temp., (
o
C)
ID – Indoor
OD –
Outdoor
5.1.4
Capacity Correction Factors
0.5
0.6
0.7
0.8
0.9
1
1.1
1.2
-15
-10
-5
0
5
10
15
Outdoor WB Temperature [deg C]
Capaci
ty
Rat
ion