3
1
1
1
3
1
5
6
10
7
8
9
4
14
13
15
11
1
12
1
1
1
1
1
1
1
1
HW
CW
8
General Hydraulic Layout for a Type 3 (*) Installation
Layout 3 :
This layout is also recommended for heating installations with wide operating water flow variations (radiator thermostatic valves present in the system). Minimum
system volume is guaranteed by a mixing tank
(10)
. Take care when calculating the volume of water in the installation and only take account of 50% of the mixing
tank's volume.
Example :
For a useful volume of 100 litres the actual mixing tank volume will be 200 litres.
The flow adjustment valve
(11)
is used to balance the flow in heating mode and domestic hot water mode to always ensure optimum PAC HT operation.
1
Stop valve
11
Flow regulating valve
3
Filter or sludge trap
12
Expansion tank
4
Relief valve
13
In-line heater
5
3-way valve - Domestic hot water
14
Bleed
6
Domestic hot water tank
15
Safety valve
7
Safety devices
HW : Hot Water
8
Recycling circulating pump (optional)
CW : Cold Water
9
Circulation pump
*
Installation components not supplied
10
Mixing tank
Summary of Contents for PAC HT 12-6
Page 19: ...19 Notes...