To ensure that the air conditioner to be used correctly and safely, please proceed the installation in accordance 
with the installation manual and read through this manual carefully before using the system.  Please keep the 
manual in a safe place after use.

O

O

This is window - type  cooling air conditioner.  The range of working temperature is between 18 C and 43 C.  
This air conditioner employ a compact structure and thus has the advantage of small power consumption.  It’s 
nominal cooling capacity can reach 3,200W.  However, the cooling efficiency of a window - type air conditioner 
depends on many factors, fo

r

 example its orientation, the indoor room temperature, frequency of opening and 

closing door, insulation of building, height of ceiling etc...

The common filter installed under the front frame at the factory can be reused after cleaning and drying.  
However, the electrostatic filter most recently developed by 3M is recommended.  This electrostatic filter  can 
filter not only filter airborne dust in the air, but also flower pollen, bacteria, nicotine, acarus and other harmful 
airborne substances.  This greatly increased the degree of air cleanness.

To prevent accidents, make sure to install a fuse for the external power supply of the air conditioner.  The fuse 
should have a rated capacity of 10A.  External power supply of the unit should be wired in accordance with the 
related national standards.  To prevent fire and accidents, extension cords should not be used.

The maximum input power and electric current specified on the label are values under the following extreme 

O

circumstances: outdoor temperature of 43 C and voltage of 230V.  Under normal circumstances, the output 
power and electric current are approximately the values specified on the label.

Noise level specified on the label is the value measured in the Noise Measurement Room at the factory.

The water-proof level specified on the label is outdoor IPX4.  The IXP4 test was conducted to the outside of 
the air conditioner under the following conditions:  the air conditioner is physically installed; the front cover of 
the unit is outside the wall, the space between the wall and the front cover and front cover is firmly sealed.

1

GENERAL INFORMATION 

RCA INST MANUAL

Summary of Contents for MAY 110

Page 1: ...Owner s Manual High Quality Window Type Room Air Conditioner MAY 110 RCA INST MANUAL...

Page 2: ...ponents 2 Control Panel 2 Preparations for Operation 3 Cooling Operation 3 Fan Operation 4 Airflow Direction Adjustment 4 Operation Maintenance and Care 5 Replacing the filter 5 Precautions 6 Before c...

Page 3: ...lso flower pollen bacteria nicotine acarus and other harmful airborne substances This greatly increased the degree of air cleanness To prevent accidents make sure to install a fuse for the external po...

Page 4: ...ntrol switch Offl Stop all operation Lo Fan Fan only operation Air delivery at low speed Hi Fan Fan only operation Air delivery at high speed Lo Cool Cooling operation at low speed Hi Cool Cooling ope...

Page 5: ...nt you desire Slowly turn the knob from the coolest point 10 The compressor will stop operating when a click sound is heard indicating that further cooling will stop The temperature controller automat...

Page 6: ...low speed and the compressor will stop operation except that the slight wind ventilate the air and eliminate dust Adjust the horizontal grille Move the adjustment plate to direct the air flow up down...

Page 7: ...e filter must be purchased from authorized dealer Note that the model number in the package of the filter must conform to that you use Remember the following suggestions so as to improve the cooling e...

Page 8: ...power plug and the lead are overheating during the unit s operation if the outer covering of the wire is damaged if foreign objects enter into the air conditioner If the water suddenly splashed on th...

Page 9: ...h window curtain etc Is the door or window open Close the entrance exit of the window Are there any obstacles blocking the ventilation of the air inlet or outlet of the air conditioner Remove the obst...

Page 10: ...ces on the parkSuite 27 8 Greenhill Road Wayville SA 5034 TEL 08 8372 7866 FAX 08 8372 7816 PERTH Suite 23 350 Cambridge St Wembley WA 6014 TEL 08 9284 0800 FAX 08 9284 0600 NEWCASTLE Suite 3 19 Darby...

Reviews: