Window F4 14 Version - 0
3. There should be no obstacle, such as a fence or wall, within 500mm from the back of the
ambient because it will prevent heat radiation of the condenser.
4. Restriction of outside air will greatly reduce the cooling and heating efficiency of the air
Conditioner.
5. Install the unit on a slight angle so that an condensate formed will not enter the room
(about 10mm or 1/4
”bubble with level).
6. Install the unit with its bottom portion 75~1500mm above the floor level.
7. The power cord must be connected to an independent circuit. The yellow/green wire must
be grounded.
8.2 Check off installation.
The setting conditions must be checked prior to initial starting. The under mentioned items are
especially important checking points when the installation is finished.
Grounding wire (yellow/Green) is provided in the power cord. The wire must be grounded.
Ensure that the unit is connected to a suitably rated and dedicated circuit.
To avoid vibration or noise, make sure the air conditioner is installed securely.
Avoid placing furniture of draperies in front of the air inlet and outlet.
8.3 How to drain.
To get the maximum cooling efficiency, the air conditioner is designed to splash the
Summary of Contents for AWWR-WDF009-C12
Page 18: ...Window F4 16 Version 0 9 Operation characteristics...
Page 28: ...Window F4 26 Version 0 12 Exploded view and part list Exploded View AWWR WDF009 C12...
Page 30: ...Window F4 28 Version 0 Exploded View AWWR WDF012 C12...
Page 32: ...Window F4 30 Version 0 Exploded view AWWR WDF018 C12...
Page 34: ...Window F4 32 Version 0 Exploded view AWWR WDF024 C12...
Page 36: ...Window F4 34 Version 0 SERVICE MANUAL Window WDF 60Hz Series...