19 | S e r v i c e M a n u a l
CONTROL SYSTEM
Auto wind control
When unit is set to auto wind by remote controller or wired controller, indoor wind speed will be
controlled abide by regulation as follow
a)
If TA -
TS≥4
℃
, at high speed
b)
If TS +3
℃
≤TA
<
TS +4
℃
, at medium speed c) If TS +2
℃
≤TA
<
TS +3
℃
, at low speed
d)
If TS≤TA
<
TS +2
℃
, at low speed intermittently
e)
If TA
<
TS, the indoor fan will restart after stop for 3 min, and operates at low wind.
Ventilation operation
Outdoor unit stay closed, indoor fan motor operates at set wind and wind speed can be set at high, medium, low by remote
controller.
Heating operation
Temperature is set by remote controller (or wired controller), temperature control range from 16
℃
- 32
℃
, user can adjust
temperature through “tempe ”and “temperature -” button on remote controller or wired controller. Press “fan speed” button to
choose fan speed among auto wind, high speed wind, medium speed wind, low speed wind.
Operation state
a
) When TA-
TS≤-1
℃
, if compressor meets 3 min protection, the compressor and outdoor fan start, indoor fan runs according to
Anti-cold air condition
b)
When TA-
TS≥1
℃
, if compressor meets 3 min continuous operation, the compressor and outdoor fan stop, indoor fan runs
according to Anti-cold air condition
c)
If TA=TS, stay in the previous state.
Summary of Contents for AWSI YIFA060-H13
Page 17: ...16 S e r v i c e M a n u a l 9 TUBING CONNECTIONS TUBING CONNECTIONS ...
Page 32: ...31 S e r v i c e M a n u a l TRUBLESHOOTING Drainage system failure ...
Page 33: ...32 S e r v i c e M a n u a l TRUBLESHOOTING Outdoor protection phase sequence ...
Page 34: ...33 S e r v i c e M a n u a l TRUBLESHOOTING Cooling high pressure protection ...
Page 35: ...34 S e r v i c e M a n u a l TRUBLESHOOTING Heating high pressure protection ...
Page 36: ...35 S e r v i c e M a n u a l TRUBLESHOOTING Cooling low pressure protection ...
Page 37: ...36 S e r v i c e M a n u a l TRUBLESHOOTING Heating low pressure protection ...
Page 38: ...37 S e r v i c e M a n u a l TRUBLESHOOTING Cooling exhaust temperature protection ...
Page 39: ...38 S e r v i c e M a n u a l TRUBLESHOOTING Heating exhaust temperature protection ...
Page 41: ...40 S e r v i c e M a n u a l TRUBLESHOOTING Sensor failure protection ...
Page 44: ...43 S e r v i c e M a n u a l TRUBLESHOOTING ...
Page 45: ...44 S e r v i c e M a n u a l TRUBLESHOOTING 11 4 3 Abnormal sound or vibration ...
Page 46: ...45 S e r v i c e M a n u a l TRUBLESHOOTING ...
Page 47: ...46 S e r v i c e M a n u a l TRUBLESHOOTING 11 4 4 Abnormal odor ...
Page 57: ......