Accessories
Console Type
141
8. Accessories
Name
Shape
Quantity
Installation fittings
Hook
2
Remote controller & Its Frame
Remote controller
1
Frame
1
Mounting screw(ST2.9×10-C-H)
2
Alkaline dry batteries (AM4)
2
Others
Installation manual
/
1
Owner's manual
/
1
9. The Specification of Power
Capacity(Btu/h)
AWSI-XAD012-N11 AWSI-XAD018-N11
Indoor Unit
Power
Phase
1-phase
Frequency and Voltage
220-240V, 50Hz
Power Wiring(mm
2
)
3×1.0
Circuit Breaker/Fuse (A)
15/10
Outdoor Unit
Power
Phase
1-phase
1-phase
Frequency and Voltage
220-240V, 50Hz
220-240V, 50Hz
Power Wiring(mm
2
)
3×1.5
3×2.5
Circuit Breaker/Fuse (A)
20/16
30/20
Indoor/Outdoor Connecting Wiring(Weak Electric Signal) (mm
2
)
3×0.2
Indoor/Outdoor Connecting Wiring(Strong Electric Signal) (mm
2
)
4×1.0
Summary of Contents for AWAU-YLD012-H11
Page 14: ...Dimensions Console Type 135 2 Dimensions AWSI XAD012 N11 AWSI XAD018 N11 ...
Page 15: ...Service Space 136 Console Type 3 Service Space ...
Page 16: ...Wiring Diagrams Console Type 137 4 Wiring Diagrams AWSI XAD012 N11 AWSI XAD018 N11 ...
Page 21: ...Field Wiring 142 Console Type 10 Field Wiring AWSI XAD012 N11 AWSI XAD018 N11 ...
Page 31: ...Wiring Diagrams 152 Outdoor Units 4 Wiring Diagrams AWAU YLD012 H11 ...
Page 33: ...Wiring Diagrams 154 Outdoor Units AWAU YLD036 H13 AWAU YLD048 H13 ...
Page 34: ...Wiring Diagrams Outdoor Units 155 AWAU YLD060 H13 ...