2-1
PRODUCT DATA SHEET
SM HDDHED 2-A.1 GB
2.1
HDD018 / HED018 // YDD 018
Model Indoor Unit
HDD/HED018
Model Outdoor Unit
YDD 018
Installation Method of Pipe
Flared
Characteristics
Units
Cooling
Heating
Capacity
(4)
kW
5.30(1.05-6.50)
5.80(1.00-7.10)
Power input
(4)
kW
1.60(0.36-2.50)
1.60(0.35-2.60)
EER (Cooling) or COP(Heating)
(4)
W/W
3.31 3.62
Energy efficiency class
A
A
Power supply
V
220-240
Ph
1
Hz
50
Rated current
A
7.2
7.2
Power factor
0.97
0.97
Prated (IDU+ODU)
W
2600
Starting current
A
Circuit breaker rating
A
25A
INDOOR
Fan type & quantity
Crossflow x 1
Fan speeds
Cooling
SH/H/M/L
RPM
1350/1100/950/800
Heating
SH/H/M/L
RPM
1400/1200/1050/900
Air flow
(1)
SH/H/M/L
m3/hr
800/680/560/460
External static pressure
Min
Pa
0
Sound power level
(2)
SH/H/M/L
dB(A)
55/50/47/39
Sound pressure level
(3)
SH/H/M/L
dB(A)
45/40/37/29
Moisture removal
l/hr
3
Condenstate drain tube I.D
mm
16
Dimensions
WxHxD
mm
865x305x215
Net Weight
kg
12
Package dimensions
WxHxD
mm
945x380x295
Packaged weight
kg
16
OUTDOOR
Refrigerant control
Capillary
Compressor type,model
Sanyo Twin Rotary,C-6RZ146H1A
Fan type & quantity
Propeller(direct) x 1
Fan speeds
H
RPM
690
Air flow
H
m3/hr
2700
Sound power level
H
dB(A)
64
Sound pressure level
(3)
H
dB(A)
54
Dimensions
WxHxD
mm
955x700x424
Net Weight
kg
52
Package dimensions
WxHxD
mm
1030x735x460
Packaged weight
kg
57
Refrigerant type
R410A
Standard charge
kg(5m)
1.25
Additional charge
20g/m(5m<L<20m)
Connections
between units
Liquid line
In.(mm)
1/4"(6.35)
Suction line
In.(mm)
1/2"(12.7)
Max.tubing length
m.
20
Max.height difference
m.
Max. 5
Operation control type
Remote control
(1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN 14511.
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.
2.
PRODUCT DATA SHEET