Maintenance operations and repairs requiring the assistance of 

other specialists must be carried out under the supervision of the 

person specialized in the use of flammable refrigerant gases.

IMPORTANT SAFETY INSTRUCTIONS

Please read this manual carefully before using the device.

This appliance is designed exclusively for household use.

It is suitable for indoor use only. Please install it in a dry place.

Regularly check the power cable. Do not use in case of damage 

to the power cable, electrical outlet or air conditioner.

An extension cord can be used if the power cable is too short. 

Be careful not to lay the cord in places where it could be pulled 

off or cause people to trip.

The air conditioner should be placed away from heat sources and out of 

direct sunlight.

Turn off the air conditioner before unplugging it.

Turn off and unplug the air conditioner before uninstalling, 

cleaning, replacing parts, or when not in use.

Follow the instructions in this manual for cleaning the air 

conditioner.

The voltage of the electrical outlet must comply with the requirements. 

Any damage resulting from incorrect power supply is not covered by 

the warranty.

Children are not allowed to play with the air conditioner.

Do not insert your fingers or other objects into the vent outlet.

Do not install the air conditioner in a place exposed to water or 

any other liquid. Make sure that water or any other liquid 

cannot enter the air conditioner.

Do not repair the air conditioner yourself. Any possible risk 

incurred due to maintenance by an inexperienced person 

would constitute a violation of the provisions of the guarantee.

If the cable or flexible outer cord of this air conditioner is 

damaged, it must be replaced exclusively by the manufacturer 
or its service agent or a person of equivalent qualification, in 
order to avoid any risk.

4

Summary of Contents for 409709

Page 1: ...INSTALLATION AND INSTRUCTION MANUAL MAINTENANCE MONOBLOC MOBILE COLD HOT AIR CONDITIONER Ref 409709 Type YPS 12HW 3 HOTLINE 1 Translated from French to English www onlinedoctranslator com...

Page 2: ...t Safety Instructions p 4 1 Overview of the air conditioner p 6 2 Installation requirements p 7 3 Control display panel and remote control p 8 4 Instructions for use p 10 5 Drainage p 14 6 Maintenance...

Page 3: ...irectives Do not puncture any component of the refrigeration circuit If the appliance is installed operated or stored in an unventilated room this must be able to prevent the stagnation of possible le...

Page 4: ...ing it Turn off and unplug the air conditioner before uninstalling cleaning replacing parts or when not in use Follow the instructions in this manual for cleaning the air conditioner The voltage of th...

Page 5: ...n upright position for at least 24 hours before starting it Use the appliance only on a horizontal and flat surface to avoid any water leakage and to ensure the correct functioning of the compressor P...

Page 6: ...pipe 1 5 meters 8 Window recessed panel 9 Remote control and its housing 10 Rear air intake grille 11 Upper filter 12 Power cable winding hook for storage 13 Carry handle 14 Air outlet to connect to t...

Page 7: ...can be placed horizontally or vertically See diagram above Adjust opening distances to bring both ends of the assembly into contact with the window frame and secure the various components of the assem...

Page 8: ...time 7 Remote control receiving window CONTROL PANEL DISPLAY SCREEN 1 COOL lamp 2 OSCILLATION air flap sweeping indicator activated 3 FAN SPEED indicator 4 DRY indicator 5 Temperature operating time i...

Page 9: ...ed on the air scavenging flaps are automatically active FAN SPEED button Successively press the button on the remote control or from the control panel to choose the desired fan speed 3 positions high...

Page 10: ...pressing the button on the control panel or the remote control COOLING COOL MODE Press the MODE button on the control panel remote control to select COOL mode Warning light Press the keys on the contr...

Page 11: ...or remote control to select DRY mode Warning light lights up on the air conditioner display Beforehand remove the cap and drain plug on the back of the air conditioner for dehumidifying water Insert...

Page 12: ...to activate the ignition delay time from 0 24H Where Programming No 2 The air conditioner running ON press the button on the control panel once or the remote control to set the stop time Press the key...

Page 13: ...er or the water outlet to the sewer or another drainage area to drain the water Refer to the instructions in chapter 5 Drainage below After draining the water the air conditioner will automatically re...

Page 14: ...y flow into the water tank Note During drainage the air conditioner may be tilted slightly backwards Once the water has been evacuated BE CAREFUL to reposition the drain plug and its cap before restar...

Page 15: ...r Manually remove the filter by gently pulling Place the filters in the warm water about 40 C added neutral detergent dry them in the shade after cleaning Proceed with the reverse operations to replac...

Page 16: ...ce the air conditioner on a flat and rigid surface avoid any surface that causes shaking The air conditioner is not placed on a suitable installation surface Too noisy The compressor does does not wor...

Page 17: ...r is responsible for disposal of this type of waste by throwing it in a recycling point specific to electrical and electronic waste Selective collection and recycling of electrical equipment helps pre...

Reviews: