8

Please make sure the operating voltage is the same as the parametric label.

For American and Canadian users, our product will be equipped with a POLARIZED AC PLUG that

will fit into the power outlet only one way. If the plug does not fit fully into the outlet, reverse the plug.

If it still does not fit, contact qualified personnel to install the proper outlet.
After inserting the plug into the outlet, the LED air quality indicator will light up and change colors

(cycle through Blue-Green-Orange-Red). Once air quality has been detected, all the lights will turn off.
The unit will enter standby mode. The power button         keeps twinkling.

1.2 Power On

• Press the button to process power.

• The blue breath light of the air quality indicator will twinkle for 15 seconds. Meanwhile, it starts to

  detect the PM2.5 value and display on the LED display.

• It goes into Auto Mode when power on.

2. Modes

2.1 Auto Mode

• It goes into Auto Mode when power on or when you press the Mode          button and choose the

  Auto Mode. 

• In Auto Mode, the Auto Mode will glow and the unit will automatically operate depending on the

  current air quality index. The LED display shows between A1, A2, A3, A4 or A5.

• It will increase the fan speed automatically to improve air quality in the room until it returns to

  healthy levels.

2.2 Manual Mode

• Press the fan speed          button to turn the unit into manual mode. Press to start air circulation.

  5 fan speeds are available. Each press will cycle between 1

2

3

4

5

1…

• When Manual Mode is selected, Auto Mode is automatically disabled.

NOTE:

 The air quality indicator changes according to the corresponding PM2.5 value.

 

2.3 Sleep Mode

• Press the Mode button          to select Sleep Mode. 

• In Sleep Mode, the fan speed will automatically be reduced to the lowest speed.

3. Child-proof Lock

• Press and hold the child lock button         for three seconds, and then the child lock will glow.

  At this time, other buttons are invalid. 

• Press and hold the child lock button for 3 seconds again to unlock it.

4. 0-24 Hour Timer

• Press the Timer button         to select the right time length.

• When the power is on, pressing the timer button will cycle through 1 hr 

 2 hrs 

 3 hrs 

 . ...

  

 24 hrs 

 0 hr etc. If the timer is set at 0 hr or restart the unit, the timer setting will be reset.

• There will be 3 seconds’delay after setting.

Summary of Contents for Glory Days AGH550

Page 1: ...HEPA Air Purifier Glory Days AGH550 USER MANUAL MANUAL DE USUARIO...

Page 2: ...SAFETY INSTRUCTIONS INSTALLATION INSTRUCTIONS CONTROLS OPERATION MAINTENANCE TROUBLESHOOTING WARRANTY PARTES ESPECIFICACIONES INSTRUCCIONES DE SEGURIDAD INSTRUCCIONES DE INSTALACI N CONTROLES OPERACI...

Page 3: ...2 English...

Page 4: ...COMPONENTS Touch control Panel Air Outlet Handle Side Air Intake 120V Power Cable Bottom Cover Bottom Air Intake 7 in 1 HEPA Filter 3...

Page 5: ...6dB 2W 40W AC 120V 60Hz 18AWG 70 inches cord 15 F 130 F 10 C 55 C CARB Certified OZONE DENSITY about HEPA AIR PURIFIER This product complies with the maximum allowable concentration of ozone of 0 050...

Page 6: ...d while the air purifier is on Do not allow children to play on or near the air purifier Use Care Always make sure to place the air purifier on a flat level surface before operation Always allow 15 in...

Page 7: ...50 is fitted with a safety cut out switch to switch the unit off if it is knocked over If the purifier is knocked over it will instantly shut off To reset simply place the purifier in an upright posit...

Page 8: ...cle between 1 2 3 4 5 1 Mode Switch Press to switch between Sleep Mode and Auto Mode 0 24 Hour Timer Press to set the desired length of operation Pressing the timer button will cycle through 1 hr 2 hr...

Page 9: ...w and the unit will automatically operate depending on the current air quality index The LED display shows between A1 A2 A3 A4 or A5 It will increase the fan speed automatically to improve air quality...

Page 10: ...se reference the United States Environmental Protection Agency EPA https cfpub epa gov airnow index cfm action aqi_brochure index particle MAINTENANCE Know the 7 in 1 HEPA Filter When the replacement...

Page 11: ...tton the fan button simultaneously for 3 seconds to reset the replacement reminder Unplug the power cord before cleaning Plastic housing should be cleaned with a soft cloth moistened with mild soap Th...

Page 12: ......

Page 13: ...to pay attention when it goes higher than 35 Allow the air purifier to run for 15S The display of the LED numbers will stabilize once air quality has been detected This PM2 5 sensor is very sensitive...

Page 14: ...ier Model AGH550 Manufacturer Warranty Period 2 Years Please keep your order receipt for future reference TERMS POLICY Quality has always been Airthereal s top priority For your 100 hassle free shoppi...

Page 15: ...sage online https airthereal com pages warranty or send an email to support airthereal com Our customer service will address your issue promptly What will Airthereal do 1 Repair the item 2 Replace the...

Page 16: ...14 Espa ol...

Page 17: ...15 PARTES Panel de control t ctil Salida de aire Manija Entrada de aire lateral Cable de alimentaci n de 120V Cubierta inferior Entrada de aire inferior Filtro HEPA 7 en 1...

Page 18: ...m xima permitida de ozono de 0 050 partes por mill n en volumen ppmv en un per odo de 24 horas La Gu a Health Canada 2010 recomienda que el l mite m ximo de exposici n basado en un tiempo promedio de...

Page 19: ...rificador de aire en un espacio cerrado donde haya gases inflamables combustibles o explosivos NO utilice en un rea donde existan vapores t xicos polvo inflamable o tanques de ox geno NO inserte dedos...

Page 20: ...de televisores radios y otros productos electr nicos La interferencia electromagn tica de ciertos electr nicos puede causar un mal funcionamiento del producto NO limpie el electrodom stico con agua o...

Page 21: ...disponibles Cada vez que presione el bot n la velocidad alternar entre 1 2 3 4 5 1 Bot n de Modo Presione para cambiar entre el Modo de Reposo y el Modo Autom tico Temporizador de 0 24 Horas Presione...

Page 22: ...encender y cambiar de color alternar entre Azul Verde Naranja Rojo Una vez haya sido detectada la calidad del aire todas las luces se apagar n La unidad entrar a modo de reposo La luz del bot n de enc...

Page 23: ...eguro para ni os durante 3 segundos 4 Temporizador de 0 24 Horas Presione el bot n del Temporizador para elegir el tiempo deseado Cuando la unidad est encendida al presionar el bot n los valores alter...

Page 24: ...hora de reemplazar el filtro de aire cuando aparezcan las siguientes se ales Aumento en el ruido Disminuci n en el flujo de aire Filtros obstruidos Presencia de malos olores en la unidad Adquiera un...

Page 25: ...meses SOLUCI N DE PROBLEMAS Problema Causa Soluci n No enciende ni responde La unidad no est conectada a una toma de corriente Conecte el enchufe a una toma de corriente el ctrica La toma de corriente...

Page 26: ...de Aire p gina 22 Inmediatamente detenga su uso y contacte a Atenci n al Cliente NO intente abrir el purificador de aire usted mismo Superficies fr giles o inclinadas resultando en un ruidos o vibrac...

Page 27: ...por un mal uso abuso negligencia alteraciones o reparaciones no autorizadas 3 Depreciaci n natural Per odo de Garant a La garant a entrar en vigencia desde la fecha original de compra y se mantendr po...

Page 28: ...ymbol on the product the operating instructions and the packaging indicate such disposal procedures The materials are recyclable in accordance with their respective symbols By means of re use material...

Reviews: