Summary of Contents for EVENING TIDE EVT-14K

Page 1: ...USER MANUAL READ AND SAVE THESE INSTRUCTIONS EVENING TIDE EVT 14K 14KW ELECTRIC TANKLESS WATER HEATER F E1 Overflow Heating Standby E2...

Page 2: ...1 CONTENTS 2 2 5 6 8 15 16 18 INTRODUCTION COMPONENTS SPECIFICATIONS IMPORTANT SAFETY INSTRUCTIONS INSTALLATION GUIDELINE CONTROLS TROUBLESHOOTING LIMITED WARRANTY...

Page 3: ...r Inlet LED Display Hot Water Outlet 2 INTRODUCTION Congratulations on your purchase and welcome to Airthereal To fully benefit from the support that Airthereal offers please register at www airtherea...

Page 4: ...3 TEMP Sensor Thermostat Heating Element Triac Transformer Relay Connection Plug To Display Water Flow Meter PRODUCT INNER STRUCTURE...

Page 5: ...UT FLOW IN DISP ELECTRICAL DIAGRAM CONNECTION DISP Connection plug to display FLOW Connection plug to the Flow Sensor IN Connection plug to the input temperature sensor OUT Connection plug to the outp...

Page 6: ...er Size Max Amperage Recommended Wire Size Min Water Flow to Activate the Unit Safe Operating Pressure Water Connections Installation Temperature Setting Dimensions LxWxH Weight SIZING GUIDE Please us...

Page 7: ...ammable vapors and liquids in the vicinity of this or any other appliance Keep rags and other combustibles away 2 FOR HOUSEHOLD INDOOR USE ONLY 3 Risk of electric shock CONNECT ONLY TO A CIRCUIT THAT...

Page 8: ...conservation are factors to be considered when selecting the water temperature setting of the water heater s thermostat Water temperatures above 125 F can cause severe burns or death from scalding Be...

Page 9: ...the water heater 2 Place the bracket on the wall and use a pencil to mark the screw hole locations Make sure the outlet and inlet are pointed downward vertically Drill four 0 24 6mm diameter holes on...

Page 10: ...the bracket with the outlet and inlet pointed downward Make sure the water heater is secure before continuing Place the bracket onto the wall and drill mounting screws directly into the plastic anchor...

Page 11: ...maintenance or service is needed 6 This product does not use a storage tank to maintain hot water therefore a temperature pressure relief valve is not required for most installations 7 It is required...

Page 12: ...nection between the panel and the heater If you have removed the panel please refer to the connection diagram on page 4 to restore the wiring to the original setting ELECTRICAL CONNECTIONS ATTENTION 1...

Page 13: ...at the circuit breaker box Serious bodily injury or death could occur if you ignore this warning 6 AWG Wire L1 Neutral wire black L2 Live wire red Confirm that your breaker panel can meet the require...

Page 14: ...liance will stay in standby 3 Press the power button on the unit to turn the appliance ON OFF When the unit is working LED lights will show the Actual Temp 4 Press and to adjust the outlet water tempe...

Page 15: ...to the normal connections 3 If the water heater is not used for a long time more than 3 months please clean the water inlet waterway first in the state of power off Not using it for a long time will...

Page 16: ...e Up Not currently working Working state Excessive water flow Leakage of electricity Temperature exceed 149 F 65 C Water inlet temperature sensor failure Water outlet temperature sensor failure No ove...

Page 17: ...f the water heater is 240v When the voltage used is lower than 240v the water heater will generate less heating power It would require a larger power model when the voltage cannot be changed You do no...

Page 18: ...in board A Check that the voltage meets the installation requirements B There is interference from high power equipment nearby Contact Airthereal support for assistance Leakage of electricity Temperat...

Page 19: ...covered 1 Damage caused by the owner when attempting to fix or altering the product by himself or herself 2 Damage caused by misuse abuse neglect alterations or unauthorized repair 3 Natural deprecia...

Page 20: ...www airthereal com Always here to help you FOR THE AIR WE CARE V 20220525 Produced for West Ryder Technology LLC 2330 Paseo Del Prado STE C304 Las Vegas NV 89102...